Skip to main content

Data interpretation · Labs

Arterial blood gas (ABG) interpretation OSCE rubric, clerkship

Oxygenation first, then the acid-base disturbance, the compensation and the cause, on the gas of a drowsy woman with severe COPD, in mmHg.

Scored at

Clerkship is where this checklist starts: 22 lines and 27 points, most of them on clinical reasoning and systematic approach.

  • 1:30 + 5:00 reading, then the room
  • 6 examiner questions
  • From clerkship
  • Free to practice, no account needed
  • Last updated
AI OSCE station · United StatesReal screen
A live AI OSCE data station from the US library: the examiner is answering the student's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · United StatesReal screen
The student's desk on a phone during an AI OSCE data station from the US library: the instructions, the ECG and the space for what the examiner hands over.

How do you want to practice?

Live with the AI1 credit, $4.90–$9Run it live

Door note

Read before you go in

Mrs. Noeline Barker, 71, has severe COPD and has been brought by EMS to the emergency department with three days of worsening shortness of breath and green sputum. She arrived on 15 liters of oxygen through a non-rebreather mask and is now drowsy. The examiner will hand you an arterial blood gas taken 20 minutes after she was changed to a 28 percent Venturi mask. Interpret it out loud and tell the examiner what you would do. You have five minutes.

1:30Read5:00In the roomTime
Ready when you are1:30

90 sec reading, then 5 min in the station

On the cart

  • Arterial blood gas printout
  • Vital signs flowsheet
  • Oxygen delivery devices for reference
Your notes from reading time

Saved in this browser only.

Clerkship is where this checklist starts: 22 lines and 27 points, most of them on clinical reasoning and systematic approach.

Clerkship standard. Interprets any gas with a reliable stepwise system, names the disturbance in full and recognizes the oxygen target for a CO2 retainer.

3 critical lines. Miss one and the station is failed, however well the rest goes.

BasicsPoints
Oxygenation
Acid-base
Compensation & gap
Other values
Synthesis
Management
Closing
0 of 22 lines checked offRunning total0/27
0 of 22 checked off, 0 of 27 points

Communication 0/2Systematic 0/5Clinical reasoning 0/14Professionalism 0/1Patient safety 0/5

Your check marks stay on this device, ready for when you come back.

How it is scored

What this station is really testing

ABG interpretation looks like arithmetic and is really a test of order. The examiner is not waiting for you to announce acidosis; they are listening for oxygenation first, then the primary disturbance, then the compensation, then the cause. Points are lost by starting at the pH, by reading the bicarbonate as a diagnosis rather than a response, and by stopping before the potassium, the lactate and the hemoglobin. A gas is a snapshot of a patient, not a puzzle, and the patient's oxygen delivery comes before the elegance of the acid-base label.

Read the rest

The second common failure is treating the numbers without the clinical context. You cannot interpret the PaO2 without knowing the FiO2, and you cannot call a raised CO2 acute or chronic until you have compared the bicarbonate with what an acute rise would produce, ideally confirmed against a previous gas. Say the normal ranges out loud, state which value explains the direction of the pH, and use the bicarbonate to date the problem. If the pH has normalized, do not congratulate yourself on compensation: think of two opposing primary disturbances until proven otherwise. Write the values down in the same order every time, because a sequence the examiner can follow is easier to score than a conclusion delivered without one.

Finish with a full sentence that names the respiratory failure, the acid-base disturbance, the compensation and the likely cause. On clerkships that sentence, a safe oxygen plan and an SBAR handoff are enough; in the final year add the NIV threshold, the treatment of the exacerbation and the goals of care. The line that saves the patient is not the anion gap, it is recognizing that the oxygen should be titrated rather than stopped, and that a pH at or below 7.35 with a PaCO2 at or above 45 is the GOLD indication for noninvasive ventilation. US gases are reported in millimeters of mercury, which is convenient, because the compensation rules are written in the same units and need no conversion.

How data interpretation stations are scored, step by step

Where the 27 points are at Clerkship

  • Communication2
  • Systematic approach5
  • Clinical reasoning14
  • Professionalism1
  • Patient safety5

3 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like at each stage

The door note reads the same at every stage of medical school. What changes is the checklist behind it.

Clerkship

22 lines, 27 points

The checklist starts here.

Interprets any gas with a reliable stepwise system, names the disturbance in full and recognizes the oxygen target for a CO2 retainer.

What lifts it to a clear pass

  • Say "what oxygen is she on?" before you read a single value — it is a point that is easy to leave on the table.
  • Do oxygenation before acid-base every time, and say out loud which type of respiratory failure this is, with the mmHg thresholds.
  • Anchor everything on the pH: the primary disturbance is whichever value explains the direction the pH has moved.
  • Finish the printout. Potassium, lactate, glucose and hemoglobin are printed there for a reason.

Final year

28 lines, 34 points

Adds six lines, most of them on clinical reasoning and patient safety.

Dates the illness from the compensation, treats the cause per GOLD, escalates to noninvasive ventilation on the right threshold and opens the goals-of-care conversation.

What lifts it to a clear pass

  • Use the bicarbonate to date the problem: a chronically raised bicarbonate means this has been going on for days, not hours.
  • Ask for the old clinic gas. Establishing the baseline turns a guess into an argument.
  • Know the NIV threshold cold: a respiratory acidosis, pH at or below 7.35 with PaCO2 at or above 45 mmHg, the GOLD criterion. A borderline gas in an improving patient can be rechecked after initial therapy, but a pH of 7.27 in a drowsy patient goes on bilevel now.
  • A pH below 7.25 belongs in the ICU with intubation actively considered — which in a smaller hospital means an early phone call about transfer.
  • Raise goals of care early — look for an advance directive or POLST and document her code status while she can still take part in the conversation.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Step 1 — oxygenation

  • Read the PaO2 with the FiO2 in front of you, because a PaO2 without an inspired oxygen is uninterpretable
  • On supplemental oxygen the PaO2 in mmHg should be roughly five times the inspired percentage, so about 140 on 28 percent, and a lower value means impaired gas exchange. The A-a gradient makes the same point: alveolar PO2 = FiO2 x 713 - PaCO2/0.8, minus the measured PaO2
  • Hypoxemic (type 1) respiratory failure is PaO2 below 60 mmHg with a normal or low PaCO2, usually a V/Q problem, treated with oxygen and the cause
  • Hypercapnic (type 2) respiratory failure is PaCO2 above 45 mmHg (some US texts say 50) with acidemia, usually with PaO2 below 60 mmHg too, a ventilation problem treated with controlled oxygen and ventilatory support
  • Cross-check the saturation against the target: roughly 92 to 96 percent for most acutely ill patients, 88 to 92 percent per GOLD if at risk of hypercapnic failure, because the target changes the order you write

Step 2 — the pH and the primary disturbance

  • pH below 7.35 is acidemia and above 7.45 is alkalemia, so state the direction before you give the diagnosis
  • The primary disturbance is the value that explains the direction the pH has moved, and if the CO2 and the bicarbonate both push it the same way there are two primary disturbances, a mixed disorder
  • Raised CO2 with acidemia is a respiratory acidosis, while low bicarbonate with acidemia is a metabolic acidosis
  • Low CO2 with alkalemia is a respiratory alkalosis, while raised bicarbonate with alkalemia is a metabolic alkalosis
  • If the pH is normal but both values are abnormal, suspect full compensation or two opposing disturbances, because a normal pH is not the same as a normal patient

Step 3 — compensation

  • The other value moves in the same direction to defend the pH, which makes it compensation rather than a second disease
  • Respiratory compensation is fast, taking minutes to hours, so a metabolic acidosis should produce immediate hyperventilation
  • Renal compensation is slow, taking one to three days, which is why a raised bicarbonate dates the respiratory problem to days rather than hours
  • An acute rise in CO2 raises bicarbonate by about 1 mEq/L per 10 mmHg while a chronic rise raises it by about 3.5 to 4, which is how you separate acute from chronic
  • Compensation rarely brings the pH back to mid-range and does not overshoot, so a pH on the far side of 7.40 means two primary disturbances

Step 4 — the rest of the printout

  • Calculate the anion gap in a metabolic acidosis: sodium minus the sum of chloride and bicarbonate, normally about 4 to 12, because a raised gap narrows the differential
  • A raised gap suggests lactate, ketones, renal failure, methanol, ethylene glycol or salicylates, and each has a different treatment
  • A normal gap suggests bicarbonate loss from diarrhea or renal tubular acidosis, and the history usually gives it away
  • Lactate above 2 suggests hypoperfusion and above 4 is a severity marker, so do not report it without acting on it
  • Read potassium, glucose, hemoglobin and carboxyhemoglobin, because they are printed on the report and they change management

The lines that earn points

Model lines for the moments this station turns on. Make them your own: anyone listening can hear a recited script.
  • Opening the presentation

    This is an arterial blood gas from Noeline Barker, taken today at 11:40 on 28 percent oxygen via a Venturi mask.
  • Putting oxygenation first

    I will start with oxygenation, because the PaO2 has to be read against the inspired oxygen before I interpret the acid-base.
  • Naming hypercapnic failure

    The PaO2 is 57 and the PaCO2 is 69, so this is hypercapnic, type 2 respiratory failure on 28 percent oxygen.
  • Naming the acid-base disturbance

    The pH is 7.27 and the CO2 is raised, so the primary disturbance is a respiratory acidosis with partial metabolic compensation.
Show the other 4
  • Dating the illness

    The bicarbonate of 30.4 is higher than an acute rise would produce, so there is a chronic component and this is acute-on-chronic.
  • Giving the oxygen plan

    I would keep her on controlled oxygen to a target of 88 to 92 percent, not stop it, and recheck the gas in 30 to 60 minutes.
  • Escalating to NIV

    With a pH of 7.27 and a PaCO2 of 69 she meets the GOLD indication for bilevel noninvasive ventilation now, and I want a senior at the bedside.
  • Handing off the consult

    Noeline Barker, 71, severe COPD, acute-on-chronic hypercapnic respiratory failure with a pH of 7.27 on 28 percent oxygen; I need senior review now for bilevel NIV, and I am continuing controlled oxygen and starting nebulizers.

How students lose points here

  • Interpreting the gas without asking what oxygen the patient was on — ask for the device and the percentage before you read a single value, because the PaO2 is uninterpretable without it.
  • Starting at the pH and calling an acidosis — assess oxygenation first and classify the respiratory failure, because the oxygen plan comes before the acid-base label.
  • Treating the raised bicarbonate as a second primary disturbance — decide whether it is compensation from the direction of the pH, because compensation never overshoots.
  • Missing the chronic component because the bicarbonate was read as a number — compare it with what an acute rise would predict, or ask for the old gas.
  • Turning the oxygen off because of the CO2 — titrate to 88 to 92 percent and recheck, because hypoxia kills faster than hypercapnia.
  • Treating a saturation of 89 percent as the whole oxygenation story — a pulse oximeter says nothing about the CO2, so a comfortable-looking number on too much oxygen can hide a climbing PaCO2 until the patient is drowsy.

Now run it live

The image or results are on your screen and an AI examiner listens, by voice, while you present them. Ask for anything else you need, then answer their questions. You are scored afterward against this checklist.1 credit, $4.90–$9 a station. No subscription, and credits never expire.
AI OSCE station · United StatesReal screen
A live AI OSCE data station from the US library: the examiner is answering the student's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · United StatesReal screen
The student's desk on a phone during an AI OSCE data station from the US library: the instructions, the ECG and the space for what the examiner hands over.
A real screen of the live room on a data station: the trace is on your desk while you present it to the examiner.