Data interpretation · Cardiovascular
ECG: bradycardia and collapse OSCE rubric, clerkship
An older woman collapses at the grocery store and her tracing is on the screen: present it in order, work out how unwell she is and say what you would do now.
Clerkship is where this checklist starts: 20 lines and 24 points, most of them on clinical reasoning and systematic approach.
- 1:30 + 8:00 reading, then the room
- 6 examiner questions
- From clerkship
- Free to practice, no account needed
- Last updated


How do you want to practice?
Read the door note, run the clock, then score yourself on the real checklist.
You present to a friend, who runs the clock and scores on their own phone.
Their score lands on your screen.
The image or results are on your screen and an AI examiner listens, by voice, while you present them.
Door note
Read before you go in
Mrs. Gloria Carter, 78, has been brought in to the emergency department by EMS after collapsing without warning at the grocery store. She was unresponsive for under a minute and is now pale and light-headed. Her 12-lead ECG is up on the screen, and the examiner holds her other results. Interpret it systematically for the examiner and outline what you would do now. You have eight minutes.
90 sec reading, then 8 min in the station
On the cart
- 12-lead ECG displayed on the workstation
- ECG calipers
- Vital signs and results, held by the examiner
- Defibrillator on the crash cart
Your notes from reading time
Saved in this browser only.

Real clinical image · James Heilman, MD · CC BY-SA 3.0, via Wikimedia Commons.
Clerkship is where this checklist starts: 20 lines and 24 points, most of them on clinical reasoning and systematic approach.
Clerkship standard. Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.
3 critical lines. Miss one and the station is failed, however well the rest goes.
Communication 0/1Systematic 0/6Clinical reasoning 0/12Professionalism 0/1Patient safety 0/4
Run the station before you look
The answers are the most useful thing on this page once you have had a go, and the least useful before.
- Marked ventricular bradycardia — count the complexes on the 10-second lead II rhythm strip along the bottom: there are five, so the ventricular rate is about 30 a minute
- The P waves are small but regular at about 75 a minute, four large boxes apart, and they march straight through the strip: the distance from each P wave to the next QRS changes with every beat. Some sit well before a QRS, some ride on a T wave and some are lost inside a QRS
- The atrial rate is faster than the ventricular rate with no fixed relationship between the two — atrioventricular dissociation, which with the atria faster means complete heart block
- The escape complexes are essentially regular and modestly widened, at about three small boxes. They are positive in I and negative in II, III and aVF, with a tall R wave and deep T wave inversion in V1 and V2 and a small r and S in V4 to V6 — consistent with a low junctional or a ventricular escape focus
- The fourth complex on the strip is the odd one out: it comes a little early, has a P wave a plausible PR ahead of it, is taller in lead II and is deeply negative at the V1 and V2 lead change. This is the chance alignment to test out loud. One beat like it, an ectopic or at most a single capture, changes neither the reading nor the plan, because no PR interval repeats
- Standard 12-lead layout: I, aVR, V1 and V4 head the columns from left to right, with the continuous lead II rhythm strip along the bottom edge
- This is a photograph of a paper printout with a pink color cast and uneven lighting. A calibration pulse about two large boxes tall sits at the far right of each row, part cropped, so 10 mm per millivolt. The paper speed is not printed and no name, date or time is visible, so say all of that out loud
When the student asks for the patient details, or the date or time of the tracing
Gloria Carter, date of birth June 22, 1948. The tracing was recorded today at 10:42 in the emergency department.CARTER, Gloria — DOB 06/22/1948 12-lead ECG recorded today at 10:42, emergency department
When the student asks about the collapse, or for the clinical context or her history
She collapsed without warning at the grocery store this morning. Bystanders say she went pale, was out for under a minute and came around quickly, with no jerking, tongue-biting or incontinence. She has been light-headed on exertion for two weeks.When the student asks the examiner to confirm the paper speed or the calibration
It was recorded at 25 millimeters per second and 10 millimeters per millivolt.When the student asks for the vital signs, the early warning score or whether a senior has been called
Heart rate 32, blood pressure 86 over 54, respiratory rate 18, saturations 95 percent on room air, temperature 97.2 Fahrenheit. She is alert lying flat, but goes gray and faint the moment she sits up.HR 32 | BP 86/54 | RR 18 | SpO2 95% on room air | Temp 97.2 °F Alert lying flat, gray and faint when sat up
When the student calls the attending or a senior to the bedside, or asks whether one has been called
The ED attending is on the way to the bedside.When the student asks about medications or rate-limiting drugs
She takes metoprolol tartrate 50 milligrams twice a day and amlodipine 5 milligrams once a day for high blood pressure, and nothing else. Her primary care physician started the metoprolol three years ago and the dose has not changed.When the student asks for the lab results, the potassium or the glucose
Potassium 4.2 on the gas, creatinine 0.8, glucose 106. High-sensitivity troponin I 6 nanograms per liter, against an upper limit of 16. Thyroid function is pending.Hgb 12.8 g/dL (12.0 - 15.5) | WBC 8.6 x10^3/uL (4.5 - 11.0) | Plt 244 x10^3/uL (150 - 400) Na 138 mEq/L (135 - 145) | K 4.2 mEq/L (3.5 - 5.0) | BUN 18 mg/dL (7 - 20) | Creatinine 0.8 mg/dL (0.6 - 1.1) | eGFR >60 (> 60) hs-Troponin I 6 ng/L (≤ 16) | Glucose 106 mg/dL (70 - 140) Mg 2.0 mg/dL (1.7 - 2.2) | Corrected Ca 9.2 mg/dL (8.5 - 10.5) | TSH pending
When the student asks whether a previous ECG is available for comparison
There is one from a pre-op clinic two years ago: sinus rhythm at 68, a PR interval of 220 milliseconds and right bundle branch block.When the student gives atropine, or asks what happens when atropine is given
Two minutes after atropine 1 milligram the ventricular rate is 34 and the blood pressure has not changed.When the student asks for transcutaneous pacing, or applies the defibrillator pacing pads
The pads are on and the defibrillator is in pacing mode.When the student sets the pacing rate or mode, turns up the current, or looks for electrical capture
At 60 milliamps there is a QRS after every pacing spike.When the student with pacing running, feels for a pulse or checks for mechanical capture
There is a femoral pulse with every paced complex. The blood pressure is 108 over 62. She is grimacing with each beat.TRANSCUTANEOUS PACING Current 60 mA. Femoral pulse with every paced complex. BP 108/62. Grimacing with each beat.
When the student gives analgesia or sedation for the pacing
She is more comfortable and the pulse is still there with every paced beat.When the student calls cardiology, asks for a transvenous pacing wire, or arranges transfer
The on-call cardiologist is on the phone.When the student examines her, or asks about her pulse, neck veins, heart sounds or lungs
The pulse is slow and regular. There are intermittent large waves in the neck veins, and the first heart sound varies in loudness. The lungs are clear.When the student asks for a repeat ECG or a longer rhythm strip
A longer strip looks the same as the one on your screen.When the student asks for IV access or for her to be put on a monitor
She is on a monitor and has an IV in her left forearm.
Present this ECG to me. · Clerkship
This is a 12-lead ECG for Gloria Carter, a 78-year-old woman with a witnessed collapse, recorded today. It is a photograph of the paper printout: the calibration pulse at the right-hand edge shows 10 millimeters per millivolt, and the paper speed is not printed, so I am assuming 25 millimeters per second. The striking abnormality is the rate: there are only five QRS complexes on the 10-second rhythm strip, giving a ventricular rate of about 30, while the P waves march through at about 75 a minute. The P-to-QRS distance changes with every beat and no PR interval repeats, so the atria and the ventricles are dissociated with the atrial rate the faster — this is third-degree, complete heart block. The escape complexes are essentially regular and modestly widened, with a tall R wave and deep T wave inversion in V1 and V2, in keeping with a low junctional or ventricular escape; the fourth complex looks different and has a P wave a plausible distance ahead of it, but no other beat repeats that distance, so I would not call the rhythm conducted. In summary: complete heart block with a slow, unreliable escape in a patient who has already had a syncopal episode and is hypotensive. This is a peri-arrest rhythm — I would attach pacing pads now, give atropine 1 milligram while they go on, and call cardiology immediately for temporary and then permanent pacing.
How unwell is she, and what would you do for her right now? · Clerkship
She is peri-arrest. A ventricular rate of about 30 with a systolic pressure of 86 after a collapse is unstable bradycardia under the ACLS algorithm, so she needs treatment now, not observation. I would get the attending to the bedside, keep her flat on a cardiac monitor with the defibrillator beside her, secure IV access and send electrolytes, a troponin and thyroid function. The pacing pads go on straight away. I would give atropine 1 milligram while they go on, repeated every 3 to 5 minutes to a maximum of 3 milligrams, but a wide escape means the block is probably below the node and atropine will probably fail, so it must not hold up transcutaneous pacing with analgesia and sedation; a dopamine infusion at 5 to 20 micrograms per kilogram per minute or an epinephrine infusion at 2 to 10 micrograms per minute is the bridge if pacing is delayed. I would hold the metoprolol and call the on-call cardiologist for a temporary transvenous wire and a permanent pacemaker, with transfer if there is no pacing service here.
Suppose she has had 1 milligram of atropine and nothing has changed. Talk me through exactly what you do next. · Final year
Atropine can be repeated every 3 to 5 minutes to a total of 3 mg, but with a wide-complex escape the block is almost certainly below the atrioventricular node and I would not stake her on it — I would move straight to transcutaneous pacing while the repeat doses are drawn up. Pads go on anteroposterior or anterolateral, the defibrillator goes into demand mode at about 70 a minute, and I increase the current from low until every pacing spike is followed by a QRS — electrical capture — and then confirm mechanical capture by palpating a femoral pulse that matches the paced rate, because chest wall twitching and spikes on the screen prove nothing on their own. Conscious patients find pacing painful, so she needs titrated analgesia and light sedation. If pacing is unavailable or capture cannot be achieved, the drug bridge is a dopamine infusion at 5 to 20 micrograms per kilogram per minute or an epinephrine infusion at 2 to 10 micrograms per minute. All of this is a bridge: she needs the on-call cardiologist, a temporary transvenous wire if she remains unstable, and a permanent pacemaker — and if this hospital has no pacing service, the transfer call starts now.
Could this be second-degree heart block? Talk me through how you would decide. · Clerkship
Both produce more P waves than QRS complexes and both sit on the risk-of-asystole list, but they read differently. In Mobitz type II, some P waves do conduct: every conducted beat carries the same, constant PR interval, and the dropped beats come intermittently or in a fixed ratio such as 2 to 1 or 3 to 1, so the R-R intervals are irregular unless the ratio is fixed. In complete heart block nothing conducts: the ventricles are driven by an independent escape, so the R-R intervals are essentially regular, the P-to-QRS distance changes with every beat, and the atrial rate is faster than the ventricular rate. The practical test is to march out the P waves and then ask whether any PR interval ever repeats — on this tracing none does, and the one complex with a P wave a plausible distance ahead of it is a single chance alignment, not a repeating PR. A 2-to-1 block is the genuinely hard case, because every second P wave is hidden in the T wave and the conducted PR is constant; a long rhythm strip, and the regularity of the escape in complete block, usually settle it.
What could have caused this rhythm in her? · Clerkship
The most common cause in an older adult is idiopathic degenerative fibrosis of the aging conducting system — Lev and Lenegre disease — and her previous tracing of first-degree block with right bundle branch block fits a system that has been failing for years. Ischemia is next: complete heart block complicates inferior infarction because the atrioventricular nodal artery usually arises from the right coronary artery, where the block is often transient and atropine-responsive, whereas block in an anterior infarct implies extensive septal necrosis and carries a far worse prognosis. Drugs matter — beta-blockers, verapamil and diltiazem, digoxin and amiodarone, especially in combination or with renal impairment — and hyperkalemia is the reversible metabolic cause to exclude on a gas. Then the rarer group: infiltration by sarcoidosis or amyloidosis, the aortic root abscess of infective endocarditis, block after cardiac surgery or transcatheter aortic valve implantation, hypothyroidism, and congenital block presenting in younger patients. Lyme carditis is the US cause not to forget: it is usually reversible with antibiotics, so a tick exposure in the Northeast or upper Midwest, especially in a younger patient, should be asked about before anyone implants a permanent device.
Suppose her rate and blood pressure improve over the next half hour. Is she safe, and what is the definitive treatment? · Final year
No. ACLS asks whether the bradycardia is causing instability; the older teaching adds four risk-of-asystole features worth knowing: recent asystole, Mobitz type II atrioventricular block, complete heart block with a wide QRS, and a ventricular pause of more than 3 seconds. She has the third — complete heart block with a widened escape — and syncope on top. Even if her rate and blood pressure improve with atropine or she stabilizes lying flat, she still needs pacing cover, so the pads stay attached, the defibrillator stays in demand mode at the bedside, and she is not left unmonitored for a moment: a distal escape is slow, fragile and can stop without warning. The definitive treatment is a permanent pacemaker, and in acquired complete heart block with intact sinus node activity that is a dual-chamber system, which paces the ventricle in time with her own P waves and restores atrioventricular synchrony; single-chamber ventricular pacing is reserved for patients in permanent atrial fibrillation. Before implantation the team excludes and treats reversible contributors — the metoprolol is withheld, potassium and thyroid function are checked, and ischemia is ruled out — although established infranodal disease like hers rarely recovers with drug withdrawal alone. She stays on a monitor with pacing cover until the device is in; a temporary transvenous wire bridges her if she remains unstable or the implant is delayed, and in a small community hospital that means transfer to a center with a pacing service. Before discharge she needs wound and device education, a pacemaker check scheduled, a discharge summary to her primary care physician, and the driving conversation: state rules vary and only a few states mandate physician reporting, so I would advise her not to drive until the pacemaker is in and cardiology has cleared her, commonly about a week after implant for a private license and longer for a commercial license under federal rules.
How it is scored
What this station is really testing
A collapse with a slow pulse is one of the highest-yield ECG stations of the clinical years, because the tracing rewards method over memorized patterns. The routine does not change — identifiers, context, calibration, then rate and rhythm — but on a very slow tracing the habits that matter are different: count the complexes on the 10-second rhythm strip and multiply by six rather than trusting 300 over the large boxes, and measure the atrial and the ventricular rates separately before you say a single word about conduction.
Read the restShow less
The skill this station actually examines is demonstrating atrioventricular dissociation out loud. March the P waves through the rhythm strip with calipers or the edge of a piece of paper and show the examiner that the P-to-QRS distance changes with every beat — some P waves fall well before the QRS, some just after it, some are buried in T waves. If no PR interval ever repeats and the atrial rate is faster than the ventricular rate, the atria and the ventricles are being run by two different pacemakers and nothing is conducting: complete heart block. The trap is the chance alignment — on any strip one or two P waves will happen to sit a plausible PR ahead of a QRS, and the student who calls those beats conducted talks themselves into second-degree block.
The top points are for treating the patient on the gurney rather than the paper. An escape rhythm at 30 a minute in a woman who has already collapsed once is a peri-arrest rhythm: a heart rate of 32 with syncope and hypotension is unstable bradycardia under ACLS before you have finished reading the strip. She gets atropine while the pacing pads go on, and a wide-complex escape warns you that atropine will probably achieve nothing, because the block sits below the atrioventricular node. The definitive answer is pacing — transcutaneous, then transvenous, then permanent — and if you are in a hospital without a pacing service, the phone call to the nearest cardiac center starts now, not after the third dose of atropine. On clerkships that means both rates, the dissociation shown on the strip, the diagnosis and the plain statement that she cannot wait. In the final year it means running the whole algorithm: atropine given with its limits understood, pads on, capture proved and the pacemaker or the transfer arranged.
Where the 24 points are at Clerkship
- Communication1
- Systematic approach6
- Clinical reasoning12
- Professionalism1
- Patient safety4
3 critical lines. Miss one and the station is failed, whatever the total.
What a pass looks like at each stage
Clerkship
20 lines, 24 points
The checklist starts here.
Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.
What lifts it to a clear pass
- On a very slow tracing, count the complexes on the 10-second rhythm strip and multiply by six — 300 over the large boxes misleads when there are only five beats to work with.
- March the P waves out with calipers or a paper edge and narrate the changing P-to-QRS distance; the examiner cannot award what you check silently.
- Never report "the PR interval" on this tracing — saying that no PR interval exists is itself the finding.
- Have the causes ready in a list: fibrosis of the conducting system, inferior infarction, rate-limiting drugs, hyperkalemia.
- Ask for the old ECG and say where you would look — the health information exchange, her primary care clinic: first-degree block with a bundle branch block two years ago turns this from a mystery into a progression.
Final year
27 lines, 32 points
Adds seven lines, most of them on patient safety and clinical reasoning.
Runs the ACLS bradycardia algorithm the way an intern at a Rapid Response would be expected to — instability named, atropine dosed correctly, pacing reached without delay and the definitive pacemaker arranged.
What lifts it to a clear pass
- Name the signs of instability — hypotension, altered mental status, shock, ischemic chest discomfort, acute heart failure — and say which ones this patient has; a heart rate of 32 with this story is unstable before you open your mouth.
- Atropine 1 mg, repeatable to 3 mg — but say in the same breath why an infranodal block with a wide escape will probably ignore it.
- Talk through transcutaneous pacing like an operator: demand mode, current up until electrical capture, then a femoral pulse to prove mechanical capture, then sedation and analgesia because it hurts.
- Recite the risk-of-asystole features and keep the pads on even when the numbers improve — the escape you are watching is the only thing keeping her alive.
- Take the story to its end: transvenous wire if she remains unstable, permanent pacemaker before discharge, metoprolol withheld, and the driving rules, which vary by state, explained to her.
A system you can run under pressure
Before you start
- Confirm the patient's name and date of birth, and the date and time the tracing was recorded — this copy carries no printed label, so ask, because reading the wrong patient's tracing is a critical error
- Ask the clinical context — a collapse with a slow pulse changes the urgency of everything that follows
- Check the calibration — the pulse at the right-hand edge of each row is about two large boxes tall, so 10 mm per millivolt, and the paper speed is not printed, so say you are assuming 25 mm per second
- Ask for a previous ECG, including anything through the health information exchange — pre-existing PR prolongation or bundle branch block tells you the conducting system has been failing for years
Two rates, measured separately
- Ventricular rate — count the QRS complexes on the 10-second rhythm strip and multiply by six; 300 over the large boxes is unreliable when there are only a handful of beats
- Atrial rate — find one clear P wave, walk that interval along the strip with calipers or a paper edge, and count the P waves the same way
- Regularity — an escape rhythm is typically metronomically regular; a slow and irregular rhythm should make you think instead of atrial fibrillation with a slow ventricular response
- QRS width of the slow complexes — narrow suggests a junctional escape at 40 to 60 a minute, wide suggests a ventricular escape at 20 to 40, and the wider and slower the escape, the less reliable it is
Proving the dissociation
- Show that the P-to-QRS distance changes with every beat — no PR interval ever repeats
- Point out P waves in impossible places: immediately after a QRS, notching an ST segment, riding on top of a T wave
- Check the atrial rate is faster than the ventricular rate — dissociation with the atria slower is a different diagnosis, an accelerated junctional rhythm outrunning the sinus node
- Actively try to disprove yourself: if any run of beats shows a constant, repeating PR interval, this is second-degree block, not complete heart block
- Name the pattern precisely: P waves regular, QRS complexes regular, each to their own clock, atria faster — third-degree (complete) atrioventricular block
The peri-arrest bradycardia approach
- Signs of instability under ACLS — hypotension, acutely altered mental status, shock, ischemic chest discomfort, acute heart failure — and her syncope: any one makes this a treat-now rhythm, and on the floor a heart rate in the 30s meets Rapid Response criteria in its own right
- First line: atropine 1 mg intravenously, repeated every 3 to 5 minutes to a maximum of 3 mg, per the AHA ACLS bradycardia algorithm
- Atropine works at the atrioventricular node, so a wide-complex infranodal escape often ignores it — never let repeated dosing delay pacing
- If atropine fails: transcutaneous pacing with analgesia and sedation, and/or a dopamine infusion at 5 to 20 micrograms per kilogram per minute or an epinephrine infusion at 2 to 10 micrograms per minute
- Risk of asystole — recent asystole, Mobitz type II block, complete heart block with a wide QRS, or a ventricular pause over 3 seconds — mandates pacing cover even if the patient momentarily improves
The lines that earn points
Confirming whose tracing it is
Before I read this, can you confirm the name, the date of birth and when it was recorded?
Counting the ventricular rate
There are five QRS complexes on this ten-second strip, so the ventricular rate is about 30 a minute.
Marching out the P waves
Walking the calipers along the strip, the P waves are regular at about 75 a minute, so the atria are running faster than the ventricles.
Testing the beat that looks conducted
This P wave sits a plausible distance before the fourth complex, but no other beat repeats that distance, so I am not calling it conducted.
Show the other 4Show fewer
Naming the rhythm
No PR interval repeats and the atria are faster, so this is third-degree, complete heart block with a slow, modestly wide escape.
Saying how sick she is
She has had syncope and her pressure is 86 over 54 with a rate of 32, so this is unstable bradycardia and it cannot wait.
Explaining the atropine decision
I will give atropine 1 milligram while the pads go on, but with a wide escape I do not expect it to work, so it will not hold up pacing.
Proving capture
There is a QRS after every spike, so that is electrical capture. Now I want a femoral pulse to prove mechanical capture, and she needs analgesia and sedation.
How students lose points here
- Calling second-degree block because one P wave happens to sit a plausible PR ahead of a QRS — chance alignments occur on every strip of complete heart block.
- Reporting a single "PR interval" measured from one beat, when the whole point of the tracing is that no PR interval ever repeats.
- Estimating the rate from one R-R pair instead of counting the 10-second strip — with five beats on the page, one pair can mislead badly.
- Giving dose after dose of atropine while the pacing pads sit in the drawer.
- Mistaking electrical capture for mechanical capture — pacing spikes on the screen mean nothing without a matching femoral pulse.
- Blaming the metoprolol alone and stopping there: established infranodal disease rarely recovers on drug withdrawal, and she still needs pacing and cardiology.
- Letting the patient off the monitor because she feels better lying flat — ventricular standstill can follow at any moment, and in a hospital without a pacing service that is also the moment the transfer call should already have been made.
Where to read more
- 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delayAmerican College of Cardiology, American Heart Association and Heart Rhythm Society · reference
- Atrioventricular blockMerck Manual, Professional Version · reference
- Adult bradycardia algorithm (2025)American Heart Association · guide
- Part 9: Adult advanced life support, 2025 AHA guidelines for CPR and emergency cardiovascular careAmerican Heart Association · guide
- BradycardiaWikEM · reference
Now run it live

