Recording a 12-lead ECG OSCE rubric, pre-clerkship

Record a 12-lead ECG on a woman brought to the ED after a dizzy spell, talked through to the examiner: who she is, where each of the ten electrodes goes, what the machine is set to, what you do when the first tracing cannot be read, and whose name is on the paper.

Scored at

Pre-clerkship is where this checklist starts: 27 lines and 32 points, most of them on systematic approach and patient safety.

  • 1:00 + 8:00 reading, then the room
  • 5 examiner questions
  • From pre-clerkship
  • Free to practice, no account needed
  • Last updated
AI OSCE station · United StatesReal screen
A live AI OSCE skills station from the US library, peripheral IV placement: the student says each step and an examiner tells them what happens. The desk shows the equipment on the cart and the student's notes.
AI OSCE station · United StatesReal screen
The student's desk on a phone during an AI OSCE knee exam from the US library: the instructions, and the vitals the examiner has just handed over.

How do you want to practice?

Live with the AI1 credit, $4.90–$9Run it live

Door note

Read before you go in

Mrs. Lorraine Petersen, 72, was brought to the emergency department of a hospital in Minneapolis, Minnesota, an hour ago after a dizzy spell while waiting for a bus. The resident looking after her has asked for a 12-lead ECG. Please record it, talking the examiner through each thing you check, say and do, and why, including exactly where each electrode goes. There is nothing to touch: the examiner will tell you what you see and what the patient says. You have eight minutes. Toward the end the examiner will ask you some questions about recording an ECG.

1:00Read8:00In the roomTime
Ready when you are1:00

1 min reading, then 8 min in the station

On the cart

  • ECG machine with a ten-wire patient cable
  • Disposable tab electrodes in a foil pack
  • Skin-cleansing wipes and gauze pads
  • Clippers and a single-use razor
  • Sheet to cover the patient
  • Alcohol-based hand rub
  • Pen
  • Sharps container and trash can
Your notes from reading time

Saved in this browser only.

Pre-clerkship is where this checklist starts: 27 lines and 32 points, most of them on systematic approach and patient safety.

Pre-clerkship standard. Records a readable tracing from correctly placed electrodes on a correctly identified patient, deals with the poor first recording at the bedside, and checks the name on the paper without being asked.

2 critical lines. Miss one and the station is failed, however well the rest goes.

PreparationPoints
Identity and consent
Position and skin
Electrode placement
Recording
The tracing and finishing
0 of 27 lines checked offRunning total0/32
0 of 27 checked off, 0 of 32 points

Communication 0/4Systematic 0/11Clinical reasoning 0/2Professionalism 0/3Patient safety 0/12

Your check marks stay on this device, ready for when you come back.

How it is scored

What this station is really testing

An ECG takes two minutes to record and is acted on for days, so the examiner is listening for the things that make a tracing true: the right patient's name on it, ten electrodes in the right places and a baseline clean enough to read. Almost every error in this station produces a tracing that still looks like an ECG. Chest electrodes put on by eye sit too high, and the result can pass for an old infarct. Limb electrodes moved to the shoulders and hips change the axis. A machine that still holds the last patient's details prints a perfectly good recording under somebody else's name. None of this is visible to the physician who reads the tracing later, which is why the points are for the method and not for getting paper out of the machine.

Read the rest

This is a talk-through, so say where your fingers go. Find the sternal angle, slide into the second space and count down to the fourth: V1 at the right sternal border, V2 at the left, V4 in the fifth space in the midclavicular line, V3 halfway between them, then V5 and V6 level with V4 in the anterior and midaxillary lines. Say that the limb electrodes go on the distal limbs, just above the wrists and ankles. Say 25 millimeters a second and 10 millimeters per millivolt. Then expect the first recording to be poor. The answer is on the stretcher and not on the machine: look at Mrs. Petersen, find out why she cannot keep still, put that right and record again. Reaching for the filter first is the wrong reflex, because it tidies the tracing by distorting it.

Before the tracing leaves the bedside, read the name printed on it. Write on it whether she had symptoms while it was recorded, then take it to someone who can read it. In the pre-clerkship years, a correctly identified patient, electrodes placed by landmark, a repeated recording after the poor one and a tracing carrying her details is the standard. In the clerkships, check the contacts before you repeat, explain why the filter stays off, annotate the tracing and say how you would spot reversed arm leads. In your final year, be able to say what misplaced electrodes do to the complexes, when posterior or right-sided leads are recorded, and how quickly a tracing must reach a reader when the patient has chest pain.

How practical skills stations are scored, step by step

Where the 32 points are at Pre-clerkship

  • Communication4
  • Systematic approach11
  • Clinical reasoning2
  • Professionalism3
  • Patient safety12

2 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like at each stage

The door note reads the same at every stage of medical school. What changes is the checklist behind it.

Pre-clerkship

27 lines, 32 points

The checklist starts here.

Records a readable tracing from correctly placed electrodes on a correctly identified patient, deals with the poor first recording at the bedside, and checks the name on the paper without being asked.

What lifts it to a clear pass

  • Learn the chest positions as a route for your finger: sternal angle, second space, count to four, right border, left border, fifth space midclavicular, halfway, then around at the same level.
  • Say V4 before V3. It shows you know why.
  • When the tracing is fuzzy, your next sentence is about the patient, not the machine.
  • Make reading the name on the printout a habit that happens before the electrodes come off.

Clerkship

32 lines, 37 points

Adds five lines, most of them on systematic approach and clinical reasoning.

Explains the reasons behind the method: why the filter stays off, why limb electrodes stay on the limbs, what goes on the tracing by hand, and how a lead reversal shows itself.

What lifts it to a clear pass

  • Know the three kinds of interference by their look: thick and fuzzy for muscle, wandering for movement or a loose electrode, fine and regular at 60 cycles for electrical interference.
  • Before repeating, press each electrode and follow each cable. Say that you are doing it.
  • Write "no chest pain at time of recording" on the tracing. The reader will look for it.
  • Negative P, QRS and T in lead I with normal chest leads is reversed arm cables until proved otherwise.

Final year

34 lines, 39 points

Adds two lines, all on clinical reasoning.

Treats the recording as the first step of a clinical decision: knows how technique falsifies a tracing, when to add leads, and how fast a tracing must be seen when the patient has symptoms.

What lifts it to a clear pass

  • Be able to say what V1 and V2 two spaces too high look like, and which diagnoses that imitates.
  • Know the posterior positions: V7, V8 and V9 at the level of V6, in the posterior axillary line, the midscapular line and the left paraspinal border.
  • In suspected acute coronary syndrome the ECG is recorded and read within 10 minutes of arrival, so it goes into a reader's hand, not into the chart.
  • Compare with a previous tracing whenever one exists, and say so.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Patient and machine

  • Ask her to state her full name and date of birth and check them against the ID wristband — two identifiers, because the tracing will be filed and compared for years
  • Look at the machine before you look at the patient: cables intact, paper loaded, battery charged, date and time right — a fault found now costs nothing
  • Clear the last patient's details and enter hers — some machines keep the previous name, and "copy" can print the previous patient's tracing
  • Explain in plain words: stickers on the chest, arms and legs, painless, a few minutes, lying still — a patient who knows it cannot hurt relaxes, and a relaxed patient gives a clean tracing
  • Offer a chaperone, draw the curtain and ask whether she has chest pain, palpitations or dizziness now — symptoms at the time of recording belong on the tracing

Position and skin

  • Have her lie back at up to about 45 degrees with arms and legs supported by the stretcher — tense or unsupported limbs put muscle signal on top of the heart's
  • Expose the chest to the waist, and cover her again once the cables are on — you cannot place by landmark through clothing, and she should not lie uncovered while you work
  • Wipe off lotion or sweat, dry the skin and rub it lightly with gauze — the electrode needs dry skin to stick to and to conduct
  • Clip hair only where an electrode will not stick, with her consent — a single-use razor, if one is used, goes in the sharps container
  • Check the electrodes are in date and the gel is moist — a dried-out electrode gives a wandering baseline

Ten electrodes

  • Limb electrodes on the forearms just above the wrists and on the lower legs just above the ankles — on the torso they change the axis and the voltages
  • Find the sternal angle, slide into the second intercostal space and count down to the fourth — V1 and V2 put on by eye are usually a space or two too high
  • V1 in the fourth space at the right sternal border, V2 in the fourth space at the left — count the left side separately, because the spaces do not always line up
  • V4 in the fifth space in the midclavicular line, then V3 midway between V2 and V4 — V4 goes on first because V3 has no landmark of its own
  • V5 in the anterior axillary line and V6 in the midaxillary line, both level with V4 — horizontal, not following the rib as it curves upward
  • Where her breast lies over the V4 to V6 positions, lift it with the back of your hand, with her permission, and place those electrodes beneath it at the same landmarks and level, not lower — that is the convention, and it keeps serial tracings comparable

Recording, and when the tracing is poor

  • Check 25 mm/s and 10 mm/mV with the muscle filter off, ask her to lie still and breathe normally, and press start — every measurement on an ECG assumes those two numbers
  • Look at the tracing before you take anything off: a steady baseline and P waves, QRS complexes and T waves you can see in every lead — otherwise it is not finished
  • If the baseline is fuzzy, look at the patient first: cold, shivering, tense, in pain or with a tremor — muscle artifact is cured at the bedside
  • Warm and reassure her, let her hands go loose, check each electrode and cable, and record again — an unreadable tracing handed on is a delay disguised as a result
  • Use the filter only when the interference cannot be removed, and write that on the tracing — it smooths the baseline by distorting the ECG

The paper

  • Read the name, date of birth and number printed on the tracing before it leaves the bedside — this is the check that catches the last patient's details
  • Write on it any symptoms during the recording and anything that was not standard — a reader cannot allow for what they have not been told
  • Take it to a physician who can read it now, and say why it was done — an ECG sitting in the chart has been recorded but not seen
  • Remove the electrodes, help her dress, throw the electrodes away, clean your hands and wipe the cables for the next patient

The lines that earn points

Model lines for the moments this station turns on. Make them your own: anyone listening can hear a recited script.
  • Confirming identity

    Can you tell me your full name and your date of birth, please? ... Thank you, I am checking that against your wristband.
  • Explaining

    This is a tracing of your heart. I will put ten sticky pads on your chest, arms and legs and clip some wires to them. It does not hurt and it takes a few minutes. I will need you to slip your gown down to your waist. Is that OK?
  • The machine

    The screen still has the last patient's name on it, so I am clearing that and entering Mrs. Petersen's name, date of birth and medical record number before I record anything.
  • Finding the fourth space

    I feel for the ridge of the sternal angle, slide across to the second space on her right and count down: second, third, fourth. V1 goes here at the edge of the sternum, and I count again on the left for V2.
Show the other 5
  • Under the breast

    I need to put three of these pads just under your left breast. May I lift it slightly with the back of my hand?
  • Before pressing start

    Twenty-five millimeters a second, ten millimeters per millivolt, filter off. Try to let your arms go floppy and breathe normally for me. No need to hold your breath.
  • After the poor tracing

    That tracing is too fuzzy to read, so I am not going to use it. You are shivering. Let me get a warm blanket over you and give you a minute to warm up, then I will check the pads and record it again.
  • Checking the paper

    Before I take anything off I am reading the top of the tracing: Lorraine Petersen, her date of birth, her number, the right date and time. I am writing "no chest pain at time of recording" on it.
  • Handing it on

    This is Mrs. Petersen's ECG, recorded just now for her dizzy spell. She had no symptoms while I recorded it. Could you look at it now, please?

How students lose points here

  • Placing V1 and V2 by eye — count down from the sternal angle, because electrodes placed by eye sit a space or two too high and can make a healthy heart look infarcted.
  • Recording under the last patient's name — look at the machine's screen before you start and at the printout before you leave.
  • Switching the filter on for a fuzzy tracing — look at the patient first, because a blanket fixes shivering and the filter only hides it.
  • Putting the limb electrodes on the shoulders and hips because it is quicker — they go above the wrists and ankles, or the axis and voltages change.
  • Handing over the first tracing with an apology — a tracing you cannot read is not a result, so repeat it.
  • Letting V5 and V6 climb with the rib — keep them on a horizontal line with V4.
  • Leaving her uncovered while you sort out the machine — cover her once the cables are on. It is her dignity, and in this station it is also the tracing.

Now run it live

An AI examiner runs the station by voice. Say each step out loud, from checks and consent to disposal, and they tell you what happens. It rehearses your sequence and your safety checks. It cannot see your hands, so practice the technique itself on a manikin.1 credit, $4.90–$9 a station. No subscription, and credits never expire.
AI OSCE station · United StatesReal screen
A live AI OSCE skills station from the US library, peripheral IV placement: the student says each step and an examiner tells them what happens. The desk shows the equipment on the cart and the student's notes.
AI OSCE station · United StatesReal screen
The student's desk on a phone during an AI OSCE knee exam from the US library: the instructions, and the vitals the examiner has just handed over.
A real screen of the live room on a skills station: you say each step and the examiner tells you what happens.