Data interpretation · Cardiovascular
ECG: bradycardia and collapse OSCE mark scheme, Year 4
An older woman collapses in a supermarket and her trace is on the screen: present it in order, work out how unwell she is and say what you would do now.
Year 4 is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and systematic approach.
- 1:30 + 8:00 reading, then the room
- 6 examiner questions
- Sat from Year 4
- Free to practise, no account needed
- Reviewed


How do you want to practise?
Read the notice, run the clock, then mark yourself on the real sheet.
You present to a friend, who runs the clock and marks on their own phone.
Their marks land on your screen.
The image or results are on your screen and an AI examiner listens, by voice, while you present them.
Candidate instructions
The notice on the door
Mrs Margaret Ellison, 78, has been brought to the emergency department after collapsing without warning in a supermarket. She was unresponsive for under a minute and is now pale and light-headed. Her 12-lead ECG is on the screen in front of you, and the examiner holds her other results. Please interpret it systematically for the examiner and outline your immediate management. You have eight minutes.
90 sec reading, then 8 min in the station
On the trolley
- 12-lead ECG displayed on the workstation
- ECG calipers
- Observation chart
- Defibrillator with pacing function on the resus trolley
Your notes from reading time
Saved in this browser only.

Real clinical image · James Heilman, MD · CC BY-SA 3.0, via Wikimedia Commons.
Year 4 is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and systematic approach.
Year 4 standard. Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.
3 critical lines. Miss one and the station is failed, however well the rest goes.
Communication 0/1Systematic 0/6Clinical reasoning 0/12Professionalism 0/1Patient safety 0/4
Run the station before you look
The answers are the most useful thing on this page once you have had a go, and the least useful before.
- Marked ventricular bradycardia — count the complexes on the 10-second lead II rhythm strip along the bottom: there are five, so the ventricular rate is about 30 a minute
- The P waves are small but regular at about 75 a minute, four large squares apart, and they march straight through the strip: the distance from each P wave to the next QRS changes with every beat. Some sit well before a QRS, some ride on a T wave and some are lost inside a QRS
- The atrial rate is faster than the ventricular rate with no fixed relationship between the two — atrioventricular dissociation, which with the atria faster means complete heart block
- The escape complexes are essentially regular and modestly broadened, at about three small squares. They are positive in I and negative in II, III and aVF, with a tall R wave and deep T wave inversion in V1 and V2 and a small r and S in V4 to V6 — consistent with a low junctional or a ventricular escape focus
- The fourth complex on the strip is the odd one out: it comes a little early, has a P wave a plausible PR ahead of it, is taller in lead II and is deeply negative at the V1 and V2 lead change. This is the chance alignment to test out loud. One beat like it, an ectopic or at most a single capture, changes neither the reading nor the plan, because no PR interval repeats
- Standard 12-lead layout: I, aVR, V1 and V4 head the columns from left to right, with the continuous lead II rhythm strip along the bottom edge
- This is a photograph of a paper printout with a pink colour cast and uneven lighting. A calibration pulse about two large squares tall sits at the far right of each row, part cropped, so 10 mm per millivolt. The paper speed is not printed and no name, date or time is visible, so say all of that out loud
When the candidate asks for the patient details, or the date or time of the trace
Margaret Ellison, date of birth 22 June 1948. The trace was recorded today at 10:42 in the emergency department.ELLISON, Margaret — DOB 22/06/1948 12-lead ECG recorded today at 10:42, emergency department
When the candidate asks about the collapse, or for the clinical context or her history
She collapsed without warning this morning. Witnesses say she went pale, was out for under a minute and came round quickly, with no jerking, tongue-biting or incontinence. She has been light-headed on exertion for two weeks.When the candidate asks the examiner to confirm the paper speed or the calibration
It was recorded at 25 millimetres per second and 10 millimetres per millivolt.When the candidate asks for the observations
Heart rate 32, blood pressure 86 over 54, respiratory rate 18, saturations 95 per cent on air, temperature 36.2. She is alert lying flat, but goes grey and faint the moment she is sat up.HR 32 | BP 86/54 | RR 18 | SpO2 95% on air | Temp 36.2 °C | GCS 15 Posture: alert lying flat, grey and faint when sat up
When the candidate asks about medications or rate-limiting drugs
She takes bisoprolol 5 milligrams and amlodipine 5 milligrams once a day for high blood pressure, and nothing else. The bisoprolol was started three years ago and the dose has not changed.When the candidate asks for the blood results, the potassium or the glucose
Potassium 4.2, creatinine 72, glucose 5.9. Troponin 6 nanograms per litre, against an upper limit of 16. Thyroid function is pending.Hb 128 g/L | WCC 8.6 x10^9/L | Plt 244 x10^9/L Na 138 mmol/L | K 4.2 mmol/L | Urea 6.4 mmol/L | Creatinine 72 umol/L | eGFR: over 60 Troponin I 6 ng/L (under 16) | Glucose 5.9 mmol/L Mg 0.84 mmol/L | Corrected Ca 2.31 mmol/L | TSH: pending
When the candidate asks whether a previous ECG is available for comparison
There is one from a pre-operative assessment two years ago: sinus rhythm at 68, a PR interval of 220 milliseconds and right bundle branch block.When the candidate gives atropine, or asks what happens when atropine is given
Two minutes after atropine 500 micrograms the ventricular rate is 34 and the blood pressure has not changed.When the candidate asks for transcutaneous pacing, or applies the defibrillator pacing pads
The pads are on and the defibrillator is in pacing mode.When the candidate sets the pacing rate or mode, turns up the current, or looks for electrical capture
At 60 milliamps there is a QRS after every pacing spike.When the candidate with pacing running, feels for a pulse or checks for mechanical capture
There is a femoral pulse with every paced complex. The blood pressure is 108 over 62. She is grimacing with each beat.TRANSCUTANEOUS PACING Current 60 mA. Femoral pulse with every paced complex. BP 108/62. Grimacing with each beat.
When the candidate gives analgesia or sedation for the pacing
She is more comfortable and the pulse is still there with every paced beat.When the candidate calls for senior help, the peri-arrest team or cardiology, or refers for pacing
The cardiology registrar is on the phone.When the candidate examines her, or asks about her pulse, neck veins, heart sounds or chest
The pulse is slow and regular. There are intermittent large waves in the neck veins, and the first heart sound varies in loudness. There are no crackles in the chest.When the candidate asks for a repeat ECG or a longer rhythm strip
A longer strip looks the same as the one on your screen.When the candidate asks for intravenous access or for her to be put on a monitor
She is on a monitor and has a cannula in her left forearm.
Present this ECG to me. · Year 4
This is a 12-lead ECG for Margaret Ellison, a 78-year-old woman with a witnessed collapse, recorded today. It is a photograph of the paper printout: the calibration pulse at the right-hand edge shows 10 millimetres per millivolt, and the paper speed is not printed, so I am assuming 25 millimetres per second. The striking abnormality is the rate: there are only five QRS complexes on the 10-second rhythm strip, giving a ventricular rate of about 30, while the P waves march through at about 75 a minute. The P-to-QRS distance changes with every beat and no PR interval repeats, so the atria and the ventricles are dissociated with the atrial rate the faster — this is third-degree, complete heart block. The escape complexes are essentially regular and modestly broadened, with a tall R wave and deep T wave inversion in V1 and V2, in keeping with a low junctional or ventricular escape; the fourth complex looks different and has a P wave a plausible distance ahead of it, but no other beat repeats that distance, so I would not call the rhythm conducted. In summary: complete heart block with a slow, unreliable escape in a patient who has already had a syncopal episode. This is a peri-arrest rhythm — I would attach pacing pads and pace now rather than give atropine, which current guidance advises against in high-degree block with a broad QRS, and refer immediately for temporary and then permanent pacing.
How unwell is she, and what would you do for her right now? · Year 4
She is peri-arrest. A ventricular rate of about 30 with a collapse and a systolic pressure of 86 gives her two life-threatening features, syncope and shock, so she needs treatment now, not observation. I would put out a peri-arrest call and ask for senior help, keep her flat on a cardiac monitor with the defibrillator beside her, secure intravenous access and send urea and electrolytes, a troponin and thyroid function. The pacing pads go on straight away. Atropine is the usual first drug for a bradycardia with adverse features, 500 micrograms repeated to a maximum of 3 milligrams, but in high-degree block with a wide QRS the 2025 Resuscitation Council UK guideline says not to give it, so I would start transcutaneous pacing with analgesia and sedation, or an isoprenaline or adrenaline infusion if pacing is delayed. I would withhold the bisoprolol, and ring cardiology for a temporary pacing wire and a permanent pacemaker.
Suppose a colleague has given her 500 micrograms of atropine and nothing has changed. Talk me through exactly what you do next. · Year 5
I would not give any more. Atropine can be repeated to 3 mg in most bradycardias, but with a broad-complex escape the block is almost certainly below the atrioventricular node, and the 2025 Resuscitation Council UK guideline advises against atropine in high-degree block with a wide QRS because it is ineffective and may worsen the block — so I would move straight to transcutaneous pacing as the bridge to a transvenous wire. Pads go on anteroposterior or anterolateral, the defibrillator goes into demand mode at about 70 a minute, and I increase the current from low until every pacing spike is followed by a QRS — electrical capture — and then confirm mechanical capture by palpating a femoral pulse that matches the paced rate, because chest wall twitching and spikes on the screen prove nothing on their own. Conscious patients find pacing painful, so she needs titrated analgesia and light sedation. If pacing is unavailable or capture cannot be achieved, the drug bridges are an isoprenaline infusion at 5 micrograms per minute or adrenaline at 2 to 10 micrograms per minute, and in extremis fist pacing at 50 to 70 a minute has a place while the kit arrives. All of this is a bridge: she needs an urgent cardiology referral for a temporary transvenous wire and a permanent pacemaker.
Could this be second-degree heart block? Talk me through how you would decide. · Year 4
Both produce more P waves than QRS complexes and both sit on the risk-of-asystole list, but they read differently. In Mobitz type II, some P waves do conduct: every conducted beat carries the same, constant PR interval, and the dropped beats come intermittently or in a fixed ratio such as 2 to 1 or 3 to 1, so the R-R intervals are irregular unless the ratio is fixed. In complete heart block nothing conducts: the ventricles are driven by an independent escape, so the R-R intervals are metronomically regular, the P-to-QRS distance changes with every beat, and the atrial rate is faster than the ventricular rate. The practical test is to march out the P waves and then ask whether any PR interval ever repeats — on this trace none does. A 2-to-1 block is the genuinely hard case, because every second P wave is invisible in the T wave and the conducted PR is constant; a long rhythm strip, and the regularity of the escape in complete block, usually settle it.
What could have caused this rhythm in her? · Year 4
The commonest cause in the UK is idiopathic degenerative fibrosis of the ageing conducting system — Lev and Lenegre disease — and her previous trace of first-degree block with right bundle branch block fits a system that has been failing for years. Ischaemia is next: complete heart block complicates inferior infarction because the atrioventricular nodal artery usually arises from the right coronary artery, where the block is often transient and atropine-responsive, whereas block in an anterior infarct implies extensive septal necrosis and carries a far worse prognosis. Drugs matter — beta-blockers, verapamil and diltiazem, digoxin and amiodarone, especially in combination or with renal impairment — and hyperkalaemia is the reversible metabolic cause to exclude on a gas. Then the rarer group: infiltration by sarcoidosis or amyloidosis, Lyme carditis, the aortic root abscess of infective endocarditis, block after cardiac surgery or transcatheter aortic valve implantation, hypothyroidism, and congenital block presenting in younger patients.
Suppose her rate and blood pressure improve over the next half hour. Is she safe, and what is the definitive treatment? · Year 5
No. The Resuscitation Council UK lists four risk-of-asystole features: recent asystole, Mobitz type II atrioventricular block, complete heart block with a broad QRS, and a ventricular pause of more than 3 seconds. She has the third — complete heart block with a broadened escape — and syncope on top. Even if her rate and blood pressure improve or she stabilises lying flat, she still needs pacing cover, so the pads stay attached, the defibrillator stays in demand mode at the bedside, and she is not left unmonitored for a moment: a distal escape is slow, fragile and can stop without warning. The definitive treatment is a permanent pacemaker, and in acquired complete heart block with intact sinus node activity that is a dual-chamber system, which paces the ventricle in time with her own P waves — NICE technology appraisal guidance recommends dual-chamber pacing over single-chamber for atrioventricular block; single-chamber ventricular pacing is reserved for patients in permanent atrial fibrillation. Before implantation the team excludes and treats reversible contributors — the bisoprolol is withheld, potassium and thyroid function are checked, and ischaemia is ruled out — although established infranodal disease like hers rarely recovers with drug withdrawal alone. A temporary transvenous wire bridges her if she remains unstable or the implant is delayed. Before discharge she needs wound and device education, a pacemaker check booked, and the driving conversation: under DVLA rules she must not drive while the block is untreated, must notify the DVLA of the pacemaker, and for a group 1 licence can usually resume driving one week after implantation once her symptoms are controlled; the group 2 rules are stricter.
How it is marked
What this station is really testing
A collapse with a slow pulse is one of the highest-yield ECG stations of the clinical years, because the trace rewards method over memorised patterns. The routine does not change — identifiers, context, calibration, then rate and rhythm — but on a very slow trace the habits that matter are different: count the complexes on the 10-second rhythm strip and multiply by six rather than trusting 300 over the large squares, and measure the atrial and the ventricular rates separately before you say a single word about conduction.
Read the restShow less
The skill this station actually examines is demonstrating atrioventricular dissociation out loud. March the P waves through the rhythm strip with calipers or the edge of a piece of paper and show the examiner that the P-to-QRS distance changes with every beat — some P waves fall well before the QRS, some just after it, some are buried in T waves. If no PR interval ever repeats and the atrial rate is faster than the ventricular rate, the atria and the ventricles are being run by two different pacemakers and nothing is conducting: complete heart block. The trap is the chance alignment — on any strip one or two P waves will happen to sit a plausible PR ahead of a QRS, and the candidate who calls those beats conducted talks themselves into second-degree block.
The top marks are for treating the patient on the trolley rather than the paper. An escape rhythm at 30 a minute in a woman who has already collapsed once is a peri-arrest rhythm: she has adverse features and the pacing pads go on now. Atropine is the first drug for most bradycardias with adverse features, but a broad-complex escape tells you the block sits below the atrioventricular node, and the 2025 Resuscitation Council UK guideline says not to give atropine in high-degree block with a wide QRS — it is ineffective and may worsen the block. The definitive answer is pacing — transcutaneous, then transvenous, then permanent — and the candidate who spends eight minutes on an elegant description while nobody has attached the defibrillator has read the trace and failed the station. At Year 4 that means both rates, the dissociation shown on the strip, the diagnosis and the plain statement that she cannot wait. At Year 5 it means running the algorithm: atropine decided with a reason, pads on, capture proved and the pacemaker arranged.
Where the 24 marks are at Year 4
- Communication1
- Systematic approach6
- Clinical reasoning12
- Professionalism1
- Patient safety4
3 critical lines. Miss one and the station is failed, whatever the total.
What a pass looks like in each year
Year 4
20 lines, 24 marks
The sheet starts here.
Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.
What lifts it to a clear pass
- On a very slow trace, count the complexes on the 10-second rhythm strip and multiply by six — 300 over the large squares misleads when there are only five beats to work with.
- March the P waves out with calipers or a paper edge and narrate the changing P-to-QRS distance; the examiner cannot award what you check silently.
- Never report "the PR interval" on this trace — saying that no PR interval exists is itself the finding.
- Have the causes ready in a list: fibrosis of the conducting system, inferior infarction, rate-limiting drugs, hyperkalaemia.
- Ask for the old ECG: first-degree block with a bundle branch block two years ago turns this from a mystery into a progression.
Year 5
27 lines, 32 marks
Adds seven lines, most of them on patient safety and clinical reasoning.
Runs the peri-arrest bradycardia algorithm — adverse features named, atropine withheld for a broad-complex block with the reason given, pacing reached without delay and the definitive pacemaker arranged.
What lifts it to a clear pass
- Name the life-threatening features in Resuscitation Council UK language — shock, syncope, myocardial ischaemia, severe heart failure, immediately post-ROSC — and say which ones this patient has.
- Know atropine — 500 micrograms, repeatable to 3 mg — and say why you are not giving it here: in high-degree block with a wide QRS it is ineffective and may worsen the block.
- Talk through transcutaneous pacing like an operator: demand mode, current up until electrical capture, then a femoral pulse to prove mechanical capture, then sedation and analgesia because it hurts.
- Recite the risk-of-asystole features and keep the pads on even when the numbers improve — the escape you are watching is the only thing keeping her alive.
- Take the story to its end: transvenous wire if she remains unstable, permanent pacemaker before discharge, bisoprolol withheld and the DVLA rules discussed.
A system you can run under pressure
Before you start
- Confirm the patient's name and date of birth, and the date and time the trace was recorded — this copy carries no printed label, so ask, because reading the wrong patient's trace is a critical error
- Ask the clinical context — a collapse with a slow pulse changes the urgency of everything that follows
- Check the calibration — the pulse at the right-hand edge of each row is about two large squares tall, so 10 mm per millivolt, and the paper speed is not printed, so say you are assuming 25 mm per second
- Ask for a previous ECG — pre-existing PR prolongation or bundle branch block tells you the conducting system has been failing for years
Two rates, measured separately
- Ventricular rate — count the QRS complexes on the 10-second rhythm strip and multiply by six; 300 over the large squares is unreliable when there are only a handful of beats
- Atrial rate — find one clear P wave, walk that interval along the strip with calipers or a paper edge, and count the P waves the same way
- Regularity — an escape rhythm is typically metronomically regular; a slow and irregular rhythm should make you think instead of atrial fibrillation with a slow ventricular response
- QRS width of the slow complexes — narrow suggests a junctional escape at 40 to 60 a minute, broad suggests a ventricular escape at 20 to 40, and the broader and slower the escape, the less reliable it is
Proving the dissociation
- Show that the P-to-QRS distance changes with every beat — no PR interval ever repeats
- Point out P waves in impossible places: immediately after a QRS, notching an ST segment, riding on top of a T wave
- Check the atrial rate is faster than the ventricular rate — dissociation with the atria slower is a different diagnosis, an accelerated junctional rhythm outrunning the sinus node
- Actively try to disprove yourself: if any run of beats shows a constant, repeating PR interval, this is second-degree block, not complete heart block
- Name the pattern precisely: P waves regular, QRS complexes regular, each to their own clock, atria faster — third-degree (complete) atrioventricular block
The peri-arrest bradycardia algorithm
- Life-threatening features — shock, syncope, myocardial ischaemia, severe heart failure, or the period immediately after ROSC: any one makes this a treat-now rhythm on the Resuscitation Council UK algorithm
- First line for most bradycardias with adverse features: atropine 500 micrograms intravenously, repeated every 3 to 5 minutes to a maximum of 3 mg — but not in high-degree atrioventricular block with a wide QRS, where the 2025 guideline says it is ineffective and may worsen the block
- Atropine acts on the sinus and atrioventricular nodes, so an infranodal block with a broad escape will not respond — go straight to pacing
- Interim measures: transcutaneous pacing with analgesia and sedation, or an isoprenaline infusion at 5 micrograms per minute or adrenaline at 2 to 10 micrograms per minute while it is set up
- Risk of asystole — recent asystole, Mobitz type II block, complete heart block with a broad QRS, or a ventricular pause over 3 seconds — mandates pacing cover even if the patient momentarily improves
The lines that carry marks
Confirming whose trace it is
Before I read this, can you confirm the name, the date of birth and when it was recorded?
Counting the ventricular rate
There are five QRS complexes on this ten-second strip, so the ventricular rate is about 30 a minute.
Marching out the P waves
Walking the calipers along the strip, the P waves are regular at about 75 a minute, so the atria are running faster than the ventricles.
Testing the beat that looks conducted
This P wave sits a plausible distance before the fourth complex, but no other beat repeats that distance, so I am not calling it conducted.
Show the other 4Show fewer
Naming the rhythm
No PR interval repeats and the atria are faster, so this is third-degree, complete heart block with a slow, modestly broad escape.
Saying how sick she is
She has had syncope and her pressure is 86 over 54. Those are life-threatening features, so this cannot wait.
Explaining the atropine decision
I would not rely on atropine here. In high-degree block with a wide QRS it is ineffective and may worsen the block, so I want the pads on now.
Proving capture
There is a QRS after every spike, so that is electrical capture. Now I want a femoral pulse to prove mechanical capture, and she needs analgesia and sedation.
How candidates lose marks here
- Calling second-degree block because one P wave happens to sit a plausible PR ahead of a QRS — chance alignments occur on every strip of complete heart block.
- Reporting a single "PR interval" measured from one beat, when the whole point of the trace is that no PR interval ever repeats.
- Estimating the rate from one R-R pair instead of counting the 10-second strip — with five beats on the page, one pair can mislead badly.
- Giving atropine to a broad-complex complete heart block — ineffective and potentially harmful — while the pacing pads sit in the drawer.
- Mistaking electrical capture for mechanical capture — pacing spikes on the screen mean nothing without a matching femoral pulse.
- Blaming the bisoprolol alone and stopping there: established infranodal disease rarely recovers on drug withdrawal, and she still needs pacing and cardiology.
- Letting the patient off the monitor because she feels better lying flat — ventricular standstill can follow at any moment.
Where to read more
- Adult advanced life support guidelines — the bradycardia algorithmResuscitation Council UK · guide
- AV block: third degree (complete heart block)LITFL · reference
- Dual-chamber pacemakers for symptomatic bradycardia (TA88)NICE · guide
- Assessing fitness to drive: a guide for medical professionalsDVLA · guide
Now sit it live