Skip to main content

Data interpretation · Cardiovascular

ECG: irregular palpitations OSCE mark scheme, Year 3

A woman with a day and a half of palpitations and a 12-lead ECG: present the trace, work out how stable she is and plan the next steps.

Marked at

Year 3 is where this sheet starts: 13 lines and 17 marks, most of them on systematic approach and clinical reasoning.

  • 1:30 + 8:00 reading, then the room
  • 6 examiner questions
  • Sat from Year 3
  • Free to practise, no account needed
  • Reviewed
AI OSCE station · UKReal screen
A live AI OSCE data station from the UK library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · UKReal screen
The candidate's desk on a phone during an AI OSCE data station from the UK library: the instructions, the ECG and the space for what the examiner hands over.

How do you want to practise?

Live with the AI1 credit, £3.67–£6Sit it live

Candidate instructions

The notice on the door

Mrs Eileen Docherty, 72, has attended the emergency department with a day and a half of fluttering in her chest and breathlessness on the stairs. Her 12-lead ECG is on the screen in front of you, and the examiner holds her other results. Please interpret it systematically for the examiner, then outline your assessment and immediate management. You have eight minutes.

1:30Read8:00In the roomBell
Ready when you are1:30

90 sec reading, then 8 min in the station

On the trolley

  • 12-lead ECG displayed on the workstation
  • ECG calipers
  • Observation chart
Your notes from reading time

Saved in this browser only.

12-lead ECG with a lead II rhythm strip — assume 25 mm/s (photograph of a printed trace)Open full size
A twelve-lead electrocardiogram printed on pink grid paper and photographed, with lead labels above each segment, three rows of leads and a single long rhythm strip running the full width of the bottom of the frame.

Real clinical image · James Heilman, MD · CC BY-SA 3.0, resized from 3741x1821 to 1600x779, re-encoded JPEG q82; no crop, no recolour, via Wikimedia Commons.

Year 3 is where this sheet starts: 13 lines and 17 marks, most of them on systematic approach and clinical reasoning.

Year 3 standard. Presents the trace with a complete, ordered sequence, uses a rate method that works for an irregular rhythm and recognises atrial fibrillation from the absent P waves and the irregularly irregular R-R intervals.

3 critical lines. Miss one and the station is failed, however well the rest goes.

BasicsMarks
Rate & rhythm
P waves & intervals
QRS, ST & T waves
Synthesis
Management
Closing
0 of 13 lines tickedRunning total0/17
0 of 13 ticked, 0 of 17 marks

Communication 0/1Systematic 0/9Clinical reasoning 0/3Professionalism 0/2Patient safety 0/2

Your ticks stay on this device, ready for when you come back.

How it is marked

What this station is really testing

Atrial fibrillation is the commonest sustained arrhythmia and the trace you are most likely to be handed — in an exam, on a ward round, or in the emergency department at 3 a.m. The sequence does not change because the diagnosis is common: confirm whose trace it is and when it was recorded, check the calibration, then work through rate, rhythm, axis, P waves, intervals, QRS complexes, ST segments and T waves before you pull it together. The one adjustment is the rate — when the rhythm is irregular, count the complexes on the 10-second rhythm strip and multiply by six, because the 300-rule assumes a regularity this trace does not have.

Read the rest

Two findings make the diagnosis, and both are negatives of a sort: no consistent P waves anywhere, and R-R intervals that vary continuously with no repeating pattern. Check more than one lead before you commit — fibrillatory undulation is easiest to separate from true atrial activity on the rhythm strip and in V1 — and know the mimics: atrial flutter with variable block keeps an organised sawtooth and ventricular rates that cluster around 150, 100 and 75, while multifocal atrial tachycardia and sinus rhythm with frequent ectopics both still have P waves. Rapid rates often bring some ST sagging in the lateral leads, and a millimetre of concave elevation in V2 and V3 is normal — describe what is there, and resist the urge to call ischaemia without a story to match.

The marks at the top end are for the patient attached to the trace. A rapid, irregular rhythm in a stable 72-year-old whose onset cannot be pinned down sets up three decisions in strict order: is she compromised enough to need synchronised cardioversion now; if not, how do you bring the rate down; and, separately from both, does her stroke risk mandate anticoagulation. That last question is the one examiners care most about, because it is the one that decides whether she has a stroke next year — and it is answered with a score, not with whether you manage to restore sinus rhythm. At Year 3 that means the sequence, a valid rate and the diagnosis; at Year 4 the mimics, the precipitants and the score; at Year 5 the whole decision, in order.

How data interpretation stations are marked, step by step

Where the 17 marks are at Year 3

  • Communication1
  • Systematic approach9
  • Clinical reasoning3
  • Professionalism2
  • Patient safety2

3 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like in each year

The notice on the door reads the same in Year 3 and in Year 5. What changes is the sheet behind it.

Year 3

13 lines, 17 marks

The sheet starts here.

Presents the trace with a complete, ordered sequence, uses a rate method that works for an irregular rhythm and recognises atrial fibrillation from the absent P waves and the irregularly irregular R-R intervals.

What lifts it to a clear pass

  • Count the complexes on the 10-second rhythm strip and multiply by six; the 300-rule assumes a regular rhythm and will mislead you here.
  • Say "irregularly irregular" only after you have mapped several R-R intervals — then commit to it out loud.
  • Hunt for P waves in more than one lead; the rhythm strip and V1 are where fibrillatory undulation is easiest to tell from true atrial activity.
  • State the technical limits — a photograph of a printed trace with the paper speed not printed — and say you are assuming 25 mm per second. It is an easy mark.

Year 4

25 lines, 30 marks

Adds twelve lines, most of them on clinical reasoning and communication.

Separates atrial fibrillation from its mimics, screens for precipitants, and pairs a first-line rate-control choice with a stroke risk calculated out loud.

What lifts it to a clear pass

  • Know the flutter giveaway: ventricular rates that cluster around 150, 100 and 75, because the atrial rate is fixed near 300 and only the block varies.
  • Run the precipitant screen every time — alcohol, thyroid, sepsis, ischaemia, pulmonary embolism, potassium and magnesium — and say which tests cover it.
  • Work through CHA2DS2-VASc component by component; a bare number without the reasoning scores less and convinces nobody.
  • Do not read rate-related ST sag, or the normal millimetre of concave elevation in V2 and V3, as ischaemia without a story to match — describe it, attribute it, move on.

Year 5

30 lines, 36 marks

Adds five lines, four on clinical reasoning and one on patient safety.

Runs the decision, not just the reading — establishes stability, respects the 48-hour rule, starts rate control and makes the anticoagulation call to a standard an FY1 would be held to.

What lifts it to a clear pass

  • Screen for adverse features first: shock, syncope, myocardial ischaemia or severe heart failure means synchronised DC cardioversion, and everything else can wait.
  • Uncertain onset is treated as more than 48 hours: no elective cardioversion until three weeks of therapeutic anticoagulation, or a transoesophageal echo has cleared the appendage.
  • Offer a DOAC first line and use ORBIT for bleeding risk — and say plainly that the anticoagulation decision stands whether or not sinus rhythm returns.
  • A resting rate under 110 is a reasonable initial target in a stable patient, tightened if symptoms persist.
  • Plan the exit: echocardiogram, cardiology follow-up, alcohol advice and a documented cardioversion decision — top candidates take the story past the department doors.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Before you start

  • Confirm the patient’s name and date of birth, and the date and time the trace was recorded — this copy carries no printed label, so ask, because reading the wrong patient’s trace is a critical error
  • Ask the clinical context — palpitations now? breathless? chest pain? — and how long the episode has lasted; duration drives the whole management pathway
  • Check calibration — the pulse at the far right of each row is about two large squares tall, so 10 mm per millivolt; the paper speed is not printed on this photographed copy, so state that you are assuming 25 mm per second
  • Check all 12 leads and the rhythm strip are present, correctly labelled and free of artefact — a noisy or mislabelled lead can imitate the very finding you are looking for
  • Ask for a previous ECG — documented sinus rhythm last year and a documented history of the same arrhythmia mean very different things today

The sequence

  • Rate — if regular, 300 divided by the large squares between R waves; if irregular, count the complexes on the 10-second rhythm strip and multiply by six, because the 300-rule assumes a regularity this rhythm does not have
  • Rhythm — regular, regularly irregular or irregularly irregular? Map several R-R intervals across the whole strip before you commit, because one pair of beats cannot separate fibrillation from ectopics
  • Axis — leads I and aVF: both positive is normal; I positive with aVF negative suggests left axis deviation, the reverse suggests right, and deviation points to conduction disease or old damage
  • P waves — present or absent, checked in more than one lead; the rhythm strip and V1 are the best hunting ground, because one flat lead proves nothing
  • Intervals — PR 120 to 200 ms when there is one to measure; QRS narrow under 120 ms; then the QT, corrected for rate, because a broad, very fast irregular trace raises pre-excitation and changes the drugs you can give
  • QRS — amplitude, pathological Q waves and R wave progression across the chest leads, because an old infarct adds to the stroke score and changes the cause you are looking for
  • ST segments and T waves — lead by lead, judged against the TP baseline and in the context of the rate, because fast rates produce sag that is not ischaemia

The irregularly irregular rhythm — a four-way split

  • Atrial fibrillation — no organised atrial activity at all: no P waves, a fibrillatory baseline, and R-R intervals that vary continuously
  • Atrial flutter with variable block — organised sawtooth flutter waves at about 300 a minute, with ventricular rates that cluster around 150, 100 and 75 as the block changes
  • Multifocal atrial tachycardia — P waves present but in three or more morphologies, classically in severe pulmonary disease
  • Sinus rhythm with frequent ectopics — an underlying sinus P wave marches through, and the irregularity comes as early beats with pauses

Rate, rhythm and the clock

  • Adverse features — shock, syncope, myocardial ischaemia or severe heart failure — mean synchronised DC cardioversion with senior support, not a prescription
  • Onset reliably within 48 hours: rate control and rhythm control are both on the table under NICE NG196 — the 2025 Resuscitation Council UK algorithm is stricter and anticoagulates once the arrhythmia has lasted more than 24 hours
  • Onset beyond 48 hours or uncertain: rate control now, and no elective cardioversion until at least three weeks of therapeutic anticoagulation — or a transoesophageal echo has excluded left atrial appendage thrombus
  • First-line rate control: a beta-blocker such as bisoprolol, or diltiazem or verapamil; digoxin when the patient is sedentary or in heart failure; never stack intravenous AV-node blockers
  • The anticoagulation decision is separate from all of the above: CHA2DS2-VASc for stroke risk, ORBIT for bleeding risk, a DOAC first line — restoring sinus rhythm does not remove the stroke risk

The lines that carry marks

Model lines for the moments this station turns on. Make them your own: examiners can hear a recited script.
  • Confirming whose trace it is

    Before I read this, can you confirm her name, her date of birth and when it was recorded?
  • Justifying the rate

    This rhythm is irregular, so I will not use the 300-rule. There are 24 complexes on this ten-second strip, which gives a rate of about 145.
  • Describing the rhythm

    The R-R intervals vary along the whole strip with no repeating pattern, and I cannot find a P wave on the rhythm strip or in V1, so the baseline looks fibrillatory.
  • Excluding flutter

    This is not flutter: there is no sawtooth in any lead, and the intervals vary continuously rather than in steps.
Show the other 4
  • Checking she is stable

    Is she in shock, has she blacked out, does she have chest pain, or is she in heart failure? Any of those would take me to cardioversion.
  • Declining cardioversion today

    She says 36 hours, but she has had shorter runs for a month, so I cannot place the onset inside 48 hours and I will not cardiovert her today.
  • Scoring the stroke risk

    One for hypertension, one for age 65 to 74 and one for female sex makes a CHA2DS2-VASc of 3, so I would offer a direct oral anticoagulant and use ORBIT to look for bleeding risks I can fix.
  • Explaining the blood thinner to her

    The tablets slow your heart, but the top chambers keep quivering, so the clot risk stays. That is why you need the blood thinner as well.

How candidates lose marks here

  • Quoting a rate from 300 divided by the large squares on an irregular trace, then defending the number.
  • Calling sinus rhythm with ectopics without checking a single lead for P waves — look at the rhythm strip and V1 before you commit.
  • Mistaking fibrillatory undulation for flutter waves; flutter keeps an organised sawtooth and its ventricular rates cluster around 150, 100 and 75.
  • Over-reading the ST segments — calling the slight J-point lift in V2 and V3, or a sub-millimetre lateral sag, ischaemia and cascading into an acute coronary syndrome pathway the history does not support.
  • Offering immediate cardioversion when the duration is uncertain and there are no adverse features — that trade is a stroke risk, not a shortcut.
  • Treating anticoagulation as optional because the plan is cardioversion — restoring sinus rhythm does not remove the stroke risk, and the decision is made on the score, not the strategy.
  • Giving an intravenous beta-blocker and verapamil together and stacking AV-node blockade.

Now sit it live

The image or results are on your screen and an AI examiner listens, by voice, while you present them. Ask for anything else you need, then answer their questions. You are marked afterwards against this mark sheet.1 credit, £3.67–£6 a station. No subscription, and credits never expire.
AI OSCE station · UKReal screen
A live AI OSCE data station from the UK library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · UKReal screen
The candidate's desk on a phone during an AI OSCE data station from the UK library: the instructions, the ECG and the space for what the examiner hands over.
A real screen of the live room on a data station: the trace is on your desk while you present it to the examiner.