Skip to main content

Data interpretation · Cardiovascular

ECG: tachycardia after an infarct OSCE mark scheme, Year 4

A man six weeks after a heart attack comes back with palpitations and light-headedness: present his 12-lead ECG and say what you would do now.

Marked at

Year 4 is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and patient safety.

  • 1:30 + 8:00 reading, then the room
  • 6 examiner questions
  • Sat from Year 4
  • Free to practise, no account needed
  • Reviewed
AI OSCE station · UKReal screen
A live AI OSCE data station from the UK library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · UKReal screen
The candidate's desk on a phone during an AI OSCE data station from the UK library: the instructions, the ECG and the space for what the examiner hands over.

How do you want to practise?

Live with the AI1 credit, £3.67–£6Sit it live

Candidate instructions

The notice on the door

Mr Dennis Whitfield, 71, was discharged six weeks ago after an anterior myocardial infarction treated with primary PCI. He has been brought back to the emergency department with 30 minutes of palpitations and light-headedness. His 12-lead ECG is on the screen in front of you, and the examiner holds his other results. Please interpret it systematically for the examiner and outline your immediate management. You have eight minutes.

1:30Read8:00In the roomBell
Ready when you are1:30

90 sec reading, then 8 min in the station

On the trolley

  • 12-lead ECG displayed on the workstation
  • Defibrillator with pads at the bedside
  • Observation chart
Your notes from reading time

Saved in this browser only.

12-lead ECG — 25 mm/s, standard calibration, with a lead II rhythm stripOpen full size
A twelve-lead electrocardiogram on scanned ruled paper, with a continuous strip along the bottom edge and square calibration marks at the left. Evenly spaced complexes fill every lead of the trace.

Real clinical image · Ksheka (original uploader at English Wikipedia) · CC BY-SA 2.5, converted greyscale PNG to RGB and re-encoded as JPEG quality 82; no resize (width 1088 is under the 1600 cap) and no crop, via Wikimedia Commons.

Year 4 is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and patient safety.

Year 4 standard. Reads the trace with a complete sequence, defaults to VT in a patient with a previous infarct, and starts the tachycardia algorithm safely — pulse, adverse features, help.

4 critical lines. Miss one and the station is failed, however well the rest goes.

BasicsMarks
Rate & rhythm
QRS & morphology
Discrimination — VT or SVT
Synthesis
Management
Closing
0 of 20 lines tickedRunning total0/24
0 of 20 ticked, 0 of 24 marks

Communication 0/2Systematic 0/4Clinical reasoning 0/9Professionalism 0/2Patient safety 0/7

Your ticks stay on this device, ready for when you come back.

How it is marked

What this station is really testing

A broad-complex tachycardia is the trace most likely to make a candidate freeze, and the one where a memorised rule does the most work: a regular broad-complex tachycardia in a patient with a previous myocardial infarction is ventricular tachycardia until proven otherwise. Read it with the same sequence you use for every ECG — basics and calibration, rate, rhythm, then the QRS itself — but read the patient first. The opening move of the station is not electrophysiology; it is confirming there is a pulse and that you are not looking at a cardiac arrest on paper.

Read the rest

The discrimination from supraventricular tachycardia with aberrant conduction matters because the errors are not symmetrical. Treat VT as though it were SVT and give verapamil, and you can abolish what little cardiac output remains; treat SVT as though it were VT and the patient is very unlikely to come to harm. Learn the features that favour VT — AV dissociation, capture and fusion beats, a very broad QRS, precordial concordance, an axis that fits no bundle branch pattern — but hold on to the pretest probability: with a scarred ventricle, the ECG features are confirmation, not the diagnosis.

The top marks in this station are for the adult tachycardia algorithm run in the right order. Screen for the life-threatening features — shock, syncope, myocardial ischaemia, severe heart failure, or the period immediately after ROSC — because they set how fast you act. Under the 2025 Resuscitation Council UK algorithm, stable VT in a scarred ventricle is still treated with synchronised cardioversion under sedation or anaesthesia, planned with an anaesthetist while the pads are already on; amiodarone is the drug option only when sedation or anaesthesia is too risky; and the moment an adverse feature appears, the shock cannot wait. Candidates who rehearse the deterioration before it happens look like doctors; candidates who meet it unprepared look like students. At Year 4 that means the pulse, the default to VT, the adverse features and a synchronised shock when he deteriorates. At Year 5 it means running both limbs with the numbers, then taking the story through to the implantable defibrillator.

How data interpretation stations are marked, step by step

Where the 24 marks are at Year 4

  • Communication2
  • Systematic approach4
  • Clinical reasoning9
  • Professionalism2
  • Patient safety7

4 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like in each year

The notice on the door reads the same in Year 3 and in Year 5. What changes is the sheet behind it.

Year 4

20 lines, 24 marks

The sheet starts here.

Reads the trace with a complete sequence, defaults to VT in a patient with a previous infarct, and starts the tachycardia algorithm safely — pulse, adverse features, help.

What lifts it to a clear pass

  • Say the rule out loud early: broad, regular and a previous infarct means VT until proven otherwise. It frames everything that follows.
  • Check the pulse and the adverse features before you polish the electrophysiology — the algorithm starts with the patient, not the trace.
  • Never let the phrase "SVT with aberrancy" pull you towards verapamil; if you are wrong, the blood pressure may not come back.
  • Measure rather than gesture: a rate near 180, a QRS over three small squares, a regular rhythm — numbers convince examiners.

Year 5

28 lines, 32 marks

Adds eight lines, all on clinical reasoning.

Runs the algorithm fluently — synchronised cardioversion under sedation planned with an anaesthetist while he is stable and delivered at once when adverse features appear, amiodarone only if sedation is too risky — and takes the story through to the implantable defibrillator.

What lifts it to a clear pass

  • Rehearse the deterioration before it happens: pads on, defibrillator in synchronised mode, anaesthetist called — so the shock follows the falling blood pressure by minutes, not by a scramble.
  • Know the numbers cold: up to three synchronised shocks from 120 to 150 joules, then amiodarone 300 mg over 10 to 20 minutes and shock again; amiodarone 300 mg over 10 to 60 minutes only for a stable patient who cannot safely be sedated.
  • Chase the potassium to at least 4.0 — coronary care units commonly aim for 4.5 to 5.0 — and the magnesium above 1.0 — low electrolytes keep the scar circuit firing.
  • Sustained VT weeks after an infarct is a secondary-prevention ICD conversation; say so, and ask for angiography to check the stent as well.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Before you start

  • Confirm the patient's name and date of birth, and the date and time the trace was recorded — this copy carries no printed label, so ask, because reading the wrong patient's trace is a critical error
  • Check the calibration — 25 mm per second and standard gain — and that all 12 leads plus a rhythm strip are present and readable, because the rate and the QRS width you are about to quote depend on it
  • Ask the clinical context before you interpret: a previous infarct changes the default diagnosis of a broad-complex tachycardia
  • Ask for a previous ECG — a broad complex that is old bundle branch block reads very differently from a broad complex that is new
  • Look up from the paper: confirm the patient has a pulse and is on a monitor before you finesse the diagnosis

Reading a broad-complex tachycardia

  • Rate — 300 divided by the large squares between R waves, or the complexes on the 10-second strip times six; here the R-R interval is about one and three quarter large squares, which is about 175 a minute
  • Regular or irregular? Regular suggests VT or SVT with aberrancy; irregular suggests AF with bundle branch block or pre-excited AF — a different and dangerous problem
  • QRS width — over 120 ms is broad; over 160 ms strongly favours a ventricular origin
  • Monomorphic or polymorphic? Identical complexes beat to beat mean monomorphic; a twisting axis means polymorphic VT and a different algorithm
  • Hunt for atrial activity — independent P waves, capture beats and fusion beats are diagnostic of VT when present, but absent in the majority

VT or SVT with aberrancy — the discriminators

  • Pretest probability first: with a previous myocardial infarction, well over 90 per cent of regular broad-complex tachycardias are VT
  • AV dissociation, capture beats or fusion beats — any one of them settles it in favour of VT
  • Precordial concordance — QRS complexes all positive or all negative from V1 to V6 — favours VT
  • Extreme axis deviation and a QRS morphology that fits neither typical right nor left bundle branch block favour VT
  • When in doubt, treat as VT. Adenosine rarely harms a ventricular rhythm; verapamil can be fatal in one

The adult tachycardia algorithm

  • Pulse first. No pulse means this is a shockable cardiac arrest — put out the 2222 call and start the ALS algorithm, not a cardioversion
  • Screen for the life-threatening features: shock, syncope, myocardial ischaemia, heart failure and the period immediately after ROSC — any one of them makes the shock immediate
  • Any of them present — synchronised DC cardioversion under sedation or anaesthesia, up to three attempts, starting at 120 to 150 joules biphasic
  • Still in the tachycardia after three shocks — amiodarone 300 mg intravenously over 10 to 20 minutes, then repeat the synchronised shock
  • None of them present — still treat as VT: synchronised cardioversion under sedation or anaesthesia is first choice; if the sedation or anaesthesia risk is too high, amiodarone 300 mg intravenously over 10 to 60 minutes through a large vein (procainamide where available) — pads on throughout, correcting potassium and magnesium in parallel

The lines that carry marks

Model lines for the moments this station turns on. Make them your own: examiners can hear a recited script.
  • Confirming whose trace it is

    Before I read this, can you confirm his name, his date of birth and when it was recorded?
  • Checking the patient first

    Before I go further, does he have a pulse, and is he on a monitor with the pads on?
  • Measuring the trace

    The R-R interval is about one and three quarter large squares, so the rate is about 175, and the QRS is well over three small squares.
  • Stating the default

    This is a regular broad-complex tachycardia in a man with a recent infarct, so it is VT until proven otherwise.
Show the other 4
  • Refusing verapamil

    If I am unsure I will treat it as VT. I would not give verapamil, because in VT it can take away what output he has left.
  • Planning while he is stable

    He has no life-threatening features right now, so I want an anaesthetist here and a synchronised shock under sedation. If sedation is too risky, amiodarone 300 milligrams over 10 to 60 minutes through a large vein.
  • When he deteriorates

    He is now shocked and drowsy, so this cannot wait. Sedation from the anaesthetist, defibrillator in synchronised mode, 120 to 150 joules.
  • If he loses his pulse

    He has lost his pulse, so this is now a cardiac arrest. Synchronisation off, and we follow the arrest algorithm.

How candidates lose marks here

  • Calling SVT with aberrancy because the patient looks well — haemodynamic stability never distinguishes SVT from VT.
  • Giving verapamil to a broad-complex tachycardia; in VT it can remove what little cardiac output remains.
  • Delivering an unsynchronised shock to a patient with a pulse — landing on the T wave can convert VT into ventricular fibrillation.
  • Forgetting sedation or anaesthesia before cardioverting a conscious patient.
  • Spending the whole station hunting for capture beats while nobody has checked the blood pressure.
  • Never asking for the potassium and magnesium — or hearing that both are low and doing nothing about it.

Now sit it live

The image or results are on your screen and an AI examiner listens, by voice, while you present them. Ask for anything else you need, then answer their questions. You are marked afterwards against this mark sheet.1 credit, £3.67–£6 a station. No subscription, and credits never expire.
AI OSCE station · UKReal screen
A live AI OSCE data station from the UK library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · UKReal screen
The candidate's desk on a phone during an AI OSCE data station from the UK library: the instructions, the ECG and the space for what the examiner hands over.
A real screen of the live room on a data station: the trace is on your desk while you present it to the examiner.