Skip to main content

Data interpretation · Cardiovascular

ECG: bradycardia and collapse OSCE mark scheme, mid clinical

An older woman collapses at the shops and her trace is on the screen: present it in order, work out how unwell she is and say what you would do now.

Marked at

Mid clinical is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and systematic approach.

  • 1:30 + 8:00 reading, then the room
  • 6 examiner questions
  • Sat from mid clinical
  • Free to practise, no account needed
  • Reviewed
AI OSCE station · AustraliaReal screen
A live AI OSCE data station from the Australian library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · AustraliaReal screen
The candidate's desk on a phone during an AI OSCE data station from the Australian library: the instructions, the ECG and the space for what the examiner hands over.

How do you want to practise?

Live with the AI1 credit, –Sit it live

Candidate instructions

The notice on the door

Mrs Noeleen Carter, 78, has been brought in to the emergency department by ambulance after collapsing without warning at the shops. She was unresponsive for under a minute and is now pale and light-headed. Her 12-lead ECG is on the screen in front of you, and the examiner holds her other results. Interpret it systematically for the examiner and outline what you would do now. You have eight minutes.

1:30Read8:00In the roomBell
Ready when you are1:30

90 sec reading, then 8 min in the station

On the trolley

  • 12-lead ECG displayed on the workstation
  • ECG calipers
  • Observation chart
  • Defibrillator with pacing function on the resus trolley
Your notes from reading time

Saved in this browser only.

12-lead ECG with a lead II rhythm strip — assume 25 mm/s (photograph of a printed trace)Open full size
A twelve-lead electrocardiogram photographed from pink ruled paper, with lead labels printed above each column and a continuous rhythm strip running along the bottom edge of the page.

Real clinical image · James Heilman, MD · CC BY-SA 3.0, via Wikimedia Commons.

Mid clinical is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and systematic approach.

Mid clinical standard. Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.

3 critical lines. Miss one and the station is failed, however well the rest goes.

BasicsMarks
Rate & rhythm
Demonstrating dissociation
Synthesis
Management
Closing
0 of 20 lines tickedRunning total0/24
0 of 20 ticked, 0 of 24 marks

Communication 0/1Systematic 0/6Clinical reasoning 0/12Professionalism 0/1Patient safety 0/4

Your ticks stay on this device, ready for when you come back.

How it is marked

What this station is really testing

A collapse with a slow pulse is one of the highest-yield ECG stations of the clinical years, because the trace rewards method over memorised patterns. The routine does not change — identifiers, context, calibration, then rate and rhythm — but on a very slow trace the habits that matter are different: count the complexes on the 10-second rhythm strip and multiply by six rather than trusting 300 over the large squares, and measure the atrial and the ventricular rates separately before you say a single word about conduction.

Read the rest

The skill this station actually examines is demonstrating atrioventricular dissociation out loud. March the P waves through the rhythm strip with calipers or the edge of a piece of paper and show the examiner that the P-to-QRS distance changes with every beat — some P waves fall well before the QRS, some just after it, some are buried in T waves. If no PR interval ever repeats and the atrial rate is faster than the ventricular rate, the atria and the ventricles are being run by two different pacemakers and nothing is conducting: complete heart block. The trap is the chance alignment — on any strip one or two P waves will happen to sit a plausible PR ahead of a QRS, and the candidate who calls those beats conducted talks themselves into second-degree block.

The top marks are for treating the patient on the trolley rather than the paper. An escape rhythm at 30 a minute in a woman who has already collapsed once is a peri-arrest rhythm: a heart rate of 32 has met MET criteria on any Australian track-and-trigger chart before you have finished reading the strip. She gets atropine while the pacing pads go on, and a broad-complex escape warns you that atropine will probably achieve nothing, because the block sits below the atrioventricular node. The definitive answer is pacing — transcutaneous, then transvenous, then permanent — and if you are in a hospital without a pacing service, the phone call to the nearest cardiac centre starts now, not after the third dose of atropine. At the mid-clinical stage that means both rates, the dissociation shown on the strip, the diagnosis and the plain statement that she cannot wait. In the final year it means running the whole approach: atropine given with its limits understood, pads on, capture proved and the pacemaker or the retrieval arranged.

How data interpretation stations are marked, step by step

Where the 24 marks are at Mid clinical

  • Communication1
  • Systematic approach6
  • Clinical reasoning12
  • Professionalism1
  • Patient safety4

3 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like at each stage

The notice on the door reads the same at every stage of the clinical years. What changes is the sheet behind it.

Mid clinical

20 lines, 24 marks

The sheet starts here.

Measures both rates, demonstrates the dissociation convincingly on the strip and names complete heart block with its common causes.

What lifts it to a clear pass

  • On a very slow trace, count the complexes on the 10-second rhythm strip and multiply by six — 300 over the large squares misleads when there are only five beats to work with.
  • March the P waves out with calipers or a paper edge and narrate the changing P-to-QRS distance; the examiner cannot award what you check silently.
  • Never report "the PR interval" on this trace — saying that no PR interval exists is itself the finding.
  • Have the causes ready in a list: fibrosis of the conducting system, inferior infarction, rate-limiting drugs, hyperkalaemia.
  • Ask for the old ECG and say where you would look — the state results network, My Health Record, her GP clinic: first-degree block with a bundle branch block two years ago turns this from a mystery into a progression.

Final year

27 lines, 32 marks

Adds seven lines, most of them on patient safety and clinical reasoning.

Runs the peri-arrest bradycardia approach the way an intern at a MET call would be expected to — adverse features named, atropine dosed correctly, pacing reached without delay and the definitive pacemaker arranged.

What lifts it to a clear pass

  • Name the adverse signs — ANZCOR lists a systolic pressure under 90, a heart rate under 40, ventricular arrhythmia and heart failure — and say which ones this patient has; a heart rate of 32 has met MET criteria before you open your mouth.
  • Atropine 600 micrograms, repeatable to 3 mg — but say in the same breath why an infranodal block with a broad escape will probably ignore it.
  • Talk through transcutaneous pacing like an operator: demand mode, current up until electrical capture, then a femoral pulse to prove mechanical capture, then sedation and analgesia because it hurts.
  • Recite the risk-of-asystole features and keep the pads on even when the numbers improve — the escape you are watching is the only thing keeping her alive.
  • Take the story to its end: transvenous wire if she remains unstable, permanent pacemaker before discharge, metoprolol withheld, and the Austroads non-driving period explained to her.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Before you start

  • Confirm the patient's name and date of birth, and the date and time the trace was recorded — this copy carries no printed label, so ask, because reading the wrong patient's trace is a critical error
  • Ask the clinical context — a collapse with a slow pulse changes the urgency of everything that follows
  • Check the calibration — the pulse at the right-hand edge of each row is about two large squares tall, so 10 mm per millivolt, and the paper speed is not printed, so say you are assuming 25 mm per second
  • Ask for a previous ECG, including anything on the state imaging and results network or My Health Record — pre-existing PR prolongation or bundle branch block tells you the conducting system has been failing for years

Two rates, measured separately

  • Ventricular rate — count the QRS complexes on the 10-second rhythm strip and multiply by six; 300 over the large squares is unreliable when there are only a handful of beats
  • Atrial rate — find one clear P wave, walk that interval along the strip with calipers or a paper edge, and count the P waves the same way
  • Regularity — an escape rhythm is typically metronomically regular; a slow and irregular rhythm should make you think instead of atrial fibrillation with a slow ventricular response
  • QRS width of the slow complexes — narrow suggests a junctional escape at 40 to 60 a minute, broad suggests a ventricular escape at 20 to 40, and the broader and slower the escape, the less reliable it is

Proving the dissociation

  • Show that the P-to-QRS distance changes with every beat — no PR interval ever repeats
  • Point out P waves in impossible places: immediately after a QRS, notching an ST segment, riding on top of a T wave
  • Check the atrial rate is faster than the ventricular rate — dissociation with the atria slower is a different diagnosis, an accelerated junctional rhythm outrunning the sinus node
  • Actively try to disprove yourself: if any run of beats shows a constant, repeating PR interval, this is second-degree block, not complete heart block
  • Name the pattern precisely: P waves regular, QRS complexes regular, each to their own clock, atria faster — third-degree (complete) atrioventricular block

The peri-arrest bradycardia approach

  • Adverse signs — ANZCOR lists a systolic pressure under 90, a heart rate under 40, ventricular arrhythmia and heart failure: any one calls for immediate treatment, she has the first two, and a heart rate in the 30s meets MET criteria in its own right
  • First line: atropine 600 micrograms intravenously — the standard Australian ampoule — repeated every 3 to 5 minutes to a maximum of 3 mg
  • Atropine works at the atrioventricular node, so a broad-complex infranodal escape often ignores it — never let repeated dosing delay pacing
  • Interim measures: transcutaneous pacing with analgesia and sedation, or an adrenaline infusion at 2 to 10 micrograms per minute — isoprenaline is an alternative where the hospital stocks it
  • Risk of asystole — recent asystole, Mobitz type II block, complete heart block with a broad QRS, or a ventricular pause over 3 seconds — mandates pacing cover even if the patient momentarily improves

The lines that carry marks

Model lines for the moments this station turns on. Make them your own: examiners can hear a recited script.
  • Confirming whose trace it is

    Before I read this, can you confirm the name, the date of birth and when it was recorded?
  • Counting the ventricular rate

    There are five QRS complexes on this ten-second strip, so the ventricular rate is about 30 a minute.
  • Marching out the P waves

    Walking the calipers along the strip, the P waves are regular at about 75 a minute, so the atria are running faster than the ventricles.
  • Testing the beat that looks conducted

    This P wave sits a plausible distance before the fourth complex, but no other beat repeats that distance, so I am not calling it conducted.
Show the other 4
  • Naming the rhythm

    No PR interval repeats and the atria are faster, so this is third-degree, complete heart block with a slow, modestly broad escape.
  • Saying how sick she is

    She has had syncope, her pressure is 86 over 54 and a rate of 32 meets MET criteria, so this cannot wait.
  • Explaining the atropine decision

    I will give atropine 600 micrograms while the pads go on, but with a broad escape I do not expect it to work, so it will not hold up pacing.
  • Proving capture

    There is a QRS after every spike, so that is electrical capture. Now I want a femoral pulse to prove mechanical capture, and she needs analgesia and sedation.

How candidates lose marks here

  • Calling second-degree block because one P wave happens to sit a plausible PR ahead of a QRS — chance alignments occur on every strip of complete heart block.
  • Reporting a single "PR interval" measured from one beat, when the whole point of the trace is that no PR interval ever repeats.
  • Estimating the rate from one R-R pair instead of counting the 10-second strip — with five beats on the page, one pair can mislead badly.
  • Giving dose after dose of atropine while the pacing pads sit in the drawer.
  • Mistaking electrical capture for mechanical capture — pacing spikes on the screen mean nothing without a matching femoral pulse.
  • Blaming the metoprolol alone and stopping there: established infranodal disease rarely recovers on drug withdrawal, and she still needs pacing and cardiology.
  • Letting the patient off the monitor because she feels better lying flat — ventricular standstill can follow at any moment, and in a hospital without a pacing service that is also the moment the retrieval call should already have been made.

Now sit it live

The image or results are on your screen and an AI examiner listens, by voice, while you present them. Ask for anything else you need, then answer their questions. You are marked afterwards against this mark sheet.1 credit, – a station. No subscription, and credits never expire.
AI OSCE station · AustraliaReal screen
A live AI OSCE data station from the Australian library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · AustraliaReal screen
The candidate's desk on a phone during an AI OSCE data station from the Australian library: the instructions, the ECG and the space for what the examiner hands over.
A real screen of the live room on a data station: the trace is on your desk while you present it to the examiner.