Skip to main content

Data interpretation · Cardiovascular

ECG: tachycardia after an infarct OSCE mark scheme, mid clinical

A man six weeks after a heart attack comes back with palpitations and light-headedness: present his 12-lead ECG and say what you would do now.

Marked at

Mid clinical is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and patient safety.

  • 1:30 + 8:00 reading, then the room
  • 6 examiner questions
  • Sat from mid clinical
  • Free to practise, no account needed
  • Reviewed
AI OSCE station · AustraliaReal screen
A live AI OSCE data station from the Australian library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · AustraliaReal screen
The candidate's desk on a phone during an AI OSCE data station from the Australian library: the instructions, the ECG and the space for what the examiner hands over.

How do you want to practise?

Live with the AI1 credit, –Sit it live

Candidate instructions

The notice on the door

Mr Graham Toohey, 71, was discharged six weeks ago after an anterior myocardial infarction treated with primary PCI at the tertiary centre. He has presented to your emergency department with 30 minutes of palpitations and light-headedness. His 12-lead ECG is on the screen in front of you, and the examiner holds his other results. Interpret it systematically for the examiner and outline what you would do now. You have eight minutes.

1:30Read8:00In the roomBell
Ready when you are1:30

90 sec reading, then 8 min in the station

On the trolley

  • 12-lead ECG displayed on the workstation
  • Defibrillator with pads at the bedside
  • Observation chart
Your notes from reading time

Saved in this browser only.

12-lead ECG — 25 mm/s, standard calibration, with a lead II rhythm stripOpen full size
A twelve-lead electrocardiogram on scanned ruled paper, with a continuous strip along the bottom edge and square calibration marks at the left. Evenly spaced complexes fill every lead of the trace.

Real clinical image · Ksheka (original uploader at English Wikipedia) · CC BY-SA 2.5, converted greyscale PNG to RGB and re-encoded as JPEG quality 82; no resize (width 1088 is under the 1600 cap) and no crop, via Wikimedia Commons.

Mid clinical is where this sheet starts: 20 lines and 24 marks, most of them on clinical reasoning and patient safety.

Mid clinical standard. Reads the trace with a complete sequence, defaults to VT in a patient with a previous infarct, and starts the tachycardia algorithm safely — pulse, adverse features, help.

4 critical lines. Miss one and the station is failed, however well the rest goes.

BasicsMarks
Rate & rhythm
QRS & morphology
Discrimination — VT or SVT
Synthesis
Management
Closing
0 of 20 lines tickedRunning total0/24
0 of 20 ticked, 0 of 24 marks

Communication 0/2Systematic 0/4Clinical reasoning 0/9Professionalism 0/2Patient safety 0/7

Your ticks stay on this device, ready for when you come back.

How it is marked

What this station is really testing

A broad-complex tachycardia is the trace most likely to make a candidate freeze, and the one where a memorised rule does the most work: a regular broad-complex tachycardia in a patient with a previous myocardial infarction is ventricular tachycardia until proven otherwise. Read it with the same sequence you use for every ECG — basics and calibration, rate, rhythm, then the QRS itself — but read the patient first. The opening move of the station is not electrophysiology; it is confirming there is a pulse and that you are not looking at a cardiac arrest on paper.

Read the rest

The discrimination from supraventricular tachycardia with aberrant conduction matters because the errors are not symmetrical. Treat VT as though it were SVT and give verapamil, and you can abolish what little cardiac output remains; treat SVT as though it were VT and the patient is very unlikely to come to harm. Learn the features that favour VT — AV dissociation, capture and fusion beats, a very broad QRS, precordial concordance, an axis that fits no bundle branch pattern — but hold on to the pretest probability: with a scarred ventricle, the ECG features are confirmation, not the diagnosis.

The top marks are for running the tachycardia algorithm in the right order, and for using the system around you. A heart rate of 176 has already met rapid response criteria in most Australian hospitals, so the MET call is not an interruption — it is the senior help and the extra hands the algorithm assumes. Screen for the adverse features — ANZCOR lists a systolic pressure under 90, a heart rate over 150, chest pain, heart failure, and drowsiness or confusion — because they choose between drugs and electricity. His rate is already on that list, so the threshold for a shock is low: amiodarone with the pads on is defensible only while his pressure and conscious level hold, and synchronised cardioversion under sedation follows the moment either slips. At the mid-clinical stage that means the pulse, the default to VT, the adverse features and a synchronised shock when he deteriorates. In the final year it means running both limbs with the numbers, then taking the story through to the implantable defibrillator.

How data interpretation stations are marked, step by step

Where the 24 marks are at Mid clinical

  • Communication2
  • Systematic approach4
  • Clinical reasoning9
  • Professionalism2
  • Patient safety7

4 critical lines. Miss one and the station is failed, whatever the total.

What a pass looks like at each stage

The notice on the door reads the same at every stage of the clinical years. What changes is the sheet behind it.

Mid clinical

20 lines, 24 marks

The sheet starts here.

Reads the trace with a complete sequence, defaults to VT in a patient with a previous infarct, and starts the tachycardia algorithm safely — pulse, adverse features, help.

What lifts it to a clear pass

  • Say the rule out loud early: broad, regular and a previous infarct means VT until proven otherwise. It frames everything that follows.
  • Check the pulse and the adverse features before you polish the electrophysiology — the algorithm starts with the patient, not the trace.
  • Never let the phrase "SVT with aberrancy" pull you towards verapamil; if you are wrong, the blood pressure may not come back.
  • A heart rate of 176 has already met rapid response criteria — say you would want the MET call out, and treat the arriving team as an asset, not an audience.

Final year

28 lines, 32 marks

Adds eight lines, all on clinical reasoning.

Runs both limbs of the algorithm fluently — amiodarone or a planned shock while his pressure holds, synchronised cardioversion under sedation the moment it falls — and takes the story through to the implantable defibrillator.

What lifts it to a clear pass

  • Rehearse the deterioration before it happens: pads on, defibrillator in synchronised mode, the MET team's airway doctor identified — so the shock follows the falling blood pressure by minutes, not by a scramble.
  • Know the numbers cold: amiodarone 300 mg over 20 to 60 minutes when stable; up to three synchronised shocks from 120 to 150 joules when not; then 300 mg over 10 to 20 minutes and shock again.
  • Chase the potassium to at least 4.0 — coronary care units commonly aim for 4.5 to 5.0 — and the magnesium above 1.0 — low electrolytes keep the scar circuit firing.
  • Sustained VT weeks after an infarct is a secondary-prevention defibrillator conversation and usually a transfer back to the tertiary centre — say so, and ask for angiography to check the stent as well.

A system you can run under pressure

Learn the sequence, not the station. A fixed order is what stops you dropping a step when the clock is running and the examiner is writing.

Before you start

  • Confirm the patient's name and date of birth, and the date and time the trace was recorded — this copy carries no printed label, so ask, because reading the wrong patient's trace is a critical error
  • Check the calibration — 25 mm per second and standard gain — and that all 12 leads plus a rhythm strip are present and readable, because the rate and the QRS width you are about to quote depend on it
  • Ask the clinical context before you interpret: a previous infarct changes the default diagnosis of a broad-complex tachycardia
  • Ask for a previous ECG — check the discharge summary from the tertiary centre and My Health Record; a broad complex that is old bundle branch block reads very differently from one that is new
  • Look up from the paper: confirm the patient has a pulse and is on a monitor before you finesse the diagnosis

Reading a broad-complex tachycardia

  • Rate — 300 divided by the large squares between R waves, or the complexes on the 10-second strip times six; here the R-R interval is about one and three quarter large squares, which is about 175 a minute
  • Regular or irregular? Regular suggests VT or SVT with aberrancy; irregular suggests AF with bundle branch block or pre-excited AF — a different and dangerous problem
  • QRS width — over 120 ms is broad; over 160 ms strongly favours a ventricular origin
  • Monomorphic or polymorphic? Identical complexes beat to beat mean monomorphic; a twisting axis means polymorphic VT and a different algorithm
  • Hunt for atrial activity — independent P waves, capture beats and fusion beats are diagnostic of VT when present, but absent in the majority

VT or SVT with aberrancy — the discriminators

  • Pretest probability first: with a previous myocardial infarction, well over 90 per cent of regular broad-complex tachycardias are VT
  • AV dissociation, capture beats or fusion beats — any one of them settles it in favour of VT
  • Precordial concordance — QRS complexes all positive or all negative from V1 to V6 — favours VT
  • Extreme axis deviation and a QRS morphology that fits neither typical right nor left bundle branch block favour VT
  • When in doubt, treat as VT. Adenosine rarely harms a ventricular rhythm; verapamil can be fatal in one

The tachycardia algorithm, the Australian way

  • Pulse first. No pulse means this is a shockable cardiac arrest — call a Code Blue and start the ANZCOR arrest algorithm, not a cardioversion
  • A heart rate of 176 meets rapid response criteria on the track-and-trigger chart — the MET call brings the airway skills and seniority the next steps need
  • Adverse features — ANZCOR lists a systolic pressure under 90, a heart rate over 150, chest pain, heart failure, and drowsiness or confusion. Unstable or deteriorating with any of them means synchronised cardioversion under procedural sedation by someone skilled in airway management, up to three attempts, starting at 120 to 150 joules biphasic
  • Still in the tachycardia after three shocks — amiodarone 300 mg intravenously over 10 to 20 minutes, then repeat the synchronised shock
  • Pressure and conscious level holding — amiodarone 300 mg intravenously over 20 to 60 minutes through a large vein, with the pads on and the defibrillator ready, correcting potassium and magnesium in parallel. His rate of 176 is itself on the ANZCOR list, so a planned shock under sedation is an equally sound first move

The lines that carry marks

Model lines for the moments this station turns on. Make them your own: examiners can hear a recited script.
  • Confirming whose trace it is

    Before I read this, can you confirm his name, his date of birth and when it was recorded?
  • Checking the patient first

    Before I go further, does he have a pulse, and is he on a monitor with the pads on?
  • Measuring the trace

    The R-R interval is about one and three quarter large squares, so the rate is about 175, and the QRS is well over three small squares.
  • Stating the default

    This is a regular broad-complex tachycardia in a man with a recent infarct, so it is VT until proven otherwise.
Show the other 4
  • Refusing verapamil

    If I am unsure I will treat it as VT. I would not give verapamil, because in VT it can take away what output he has left.
  • Planning while he is stable

    His pressure and conscious level are holding, so I would give amiodarone 300 milligrams over 20 to 60 minutes through a large vein, with the pads on and the MET team here, and shock him the moment either falls.
  • When he deteriorates

    He is now shocked and drowsy, so this cannot wait. Procedural sedation from the anaesthetist, defibrillator in synchronised mode, 120 to 150 joules.
  • If he loses his pulse

    He has lost his pulse, so this is now a Code Blue. Synchronisation off, and we follow the ANZCOR arrest algorithm.

How candidates lose marks here

  • Calling SVT with aberrancy because the patient looks well — haemodynamic stability never distinguishes SVT from VT.
  • Giving verapamil to a broad-complex tachycardia; in VT it can remove what little cardiac output remains.
  • Delivering an unsynchronised shock to a patient with a pulse — landing on the T wave can convert VT into ventricular fibrillation.
  • Forgetting procedural sedation before cardioverting a conscious patient, or delivering it without someone skilled in airway management.
  • Treating the MET call as an interruption rather than as the senior help and extra hands the algorithm assumes.
  • Spending the whole station hunting for capture beats while nobody has checked the blood pressure.
  • Never asking for the potassium and magnesium — or hearing that both are low and doing nothing about it.

Now sit it live

The image or results are on your screen and an AI examiner listens, by voice, while you present them. Ask for anything else you need, then answer their questions. You are marked afterwards against this mark sheet.1 credit, – a station. No subscription, and credits never expire.
AI OSCE station · AustraliaReal screen
A live AI OSCE data station from the Australian library: the examiner is answering the candidate's question about whose trace it is, with the 12-lead ECG and the patient details on the desk.
AI OSCE station · AustraliaReal screen
The candidate's desk on a phone during an AI OSCE data station from the Australian library: the instructions, the ECG and the space for what the examiner hands over.
A real screen of the live room on a data station: the trace is on your desk while you present it to the examiner.